2008 27 210OPTRS
C. WINTERIZATION
To winterize the Model 210 water system, the system should be filled with a solution of
propylene glycol. Follow procedures outlined below:
1. Disconnect siphon hose from water tank.
2. Submerge hose end into container of propylene glycol.
3. Turn ignition switch on. Turn water switch on until propylene glyco is observed to
spray from nozzles. Then turn water switch off.
4. Make sure water tank is DRAINED!
5. System is now winterized.
WISCONSIN POWER UNIT STARTING PROCEDURE:
If sweeper is equipped with the Wis-Con Power unit, follow the procedure below to start the en
-
gine.
1. Make sure the throttle is fully shut and the choke is OFF (Plate Open).
2. Engage the starter, spin engine for 3 seconds to allow engine speed to increase, then
pull the choke cable fully out (Plate Closed). Push back in when the engine fires. Choke
plate should not have to be closed for more than several seconds even in cold climates.
3. If the engine stalls, repeat the procedure, this time pushing the choke in slower after the
engine fires.
4. Choking may not be necessary for hot restarts. If required, use only a quick pull of the
choke after the engine is spinning, with an immediate return to open position.