17
Starting an Electric Start Unit
Tostartyourpressureblasterforthersttime,followtheseinstruc-
tions step-by-step. This starting information also applies if you have
let the pressure blaster sit idle for at least a day.
• Unit is shipped with battery cables disconnected.
• Attachpositive(red)leadrst.
• Attach negative (black) lead last.
• Rotate the fuel valve to the ‘on’ position.
• Move choke to the ‘closed’ or ‘start’ position. Consult your engine
manual.
• Assure the throttle is pushed to the left.
• Turn key to the ‘start’ position.
• Once engine starts, return key to the ‘run’ position.
• Move choke to the ‘open’ or ‘run’ position.
DO NOT run the pump without the water supply
connected and turned on.
• Damage to equipment resulting from failure to follow this
instruction will void warranty.