SARA-G3 series - System Integration Manual
UBX-13000995 - R06 Objective Specification System description
Page 59 of 218
If HW flow control is enabled, the hardware flow-control output (CTS line) indicates when the UART
interface is enabled (data can be sent and received) as illustrated in Figure 19Figure 19.
time [s]
CTS ON
CTS OFF
UART disabled
~10 ms (min)
UART enabled
~9.2 s (default)
UART enabled
Data input
0.47- 2.10 s
Figure 19: CTS behavior with power saving enabled (AT+UPSV=1) and HW flow control enabled: the CTS output line indicates when the
UART interface of the module is enabled (CTS = ON = low level) or disabled (CTS = OFF = high level)