PAGE 4 OF 18 1022 IH-161
MODEL SOURCE
IMPULSE
POWER
MAX. SEAL
LENGTH
MAX. SEAL
THICKNESS
WEIGHT DIMENSIONS
H-458 120 V 160 W 4" 8 Mil 3.7 lbs. 2.8 x 8.3 x 5.9"
H-161 120 V 410 W 8" 8 Mil 7.7 lbs. 3.2 x 15 x 6.3"
H-163 120 V 410 W 8" 8 Mil 5.8 lbs. 3.2 x 12.6 x 5.9"
H-190 120 V 580 W 12" 8 Mil 8.5 lbs. 3.3 x 17.8 x 7.4"
H-293 120 V 580 W 12" 8 Mil 10.1 lbs. 3.2 x 17.9 x 7.4"
H-306 120 V 670 W 16" 8 Mil 9.9 lbs. 3 x 21 x 7"
H-963 120 V 670 W 16" 8 Mil 11.9 lb s. 3.2 x 21.8 x 7.3"
H-1029 120 V 870 W 20" 8 Mil 13 lbs. 4.5 x 28 x 7.8"
H-1252 120 V 870 W 20" 8 Mil 13 lbs. 3.2 x 25.9 x 7.4"
SEALER SPECIFICATIONS
SPECIFICATIONS CONTINUED
OPERATING ISSUE RECOMMENDATIONS
Sealer stops sealing and the sealing light does not
come on.
The arm may not be activating the microswitch.
1. Unplug unit.
2. Unscrew rubber foot screws to remove bottom.
3. Turn sealer upside down, and press down to see
if activation screw extends to activate black
microswitch button. You should hear a "click"
(see photo).
4. If it does not "click", extend activation screw
approximately 1/16 to 1/8".
5. Continue to adjust and test until you hear a "click".
TROUBLESHOOTING
TIPS:
Always keep sealing platform clean. Do not use water
to clean sealing platform.
Only use ULINE replacement parts and service kits.
A short circuit will occur if the bottom teflon cloth strip
wears out. Check the bottom teflon tape for wear
and damage when replacing heating element or top
teflon cover.
A worn rubber pressure pad (under the handle) will
influence the quality of the seals. The rubber pad
should be periodically checked for uneven wear.
If the bag seal is damaged or broken, it is because
the heating time is too long. Reset the timer knob to a
lower number. Reference Settings Chart on page 3.
If the plastic bag sticks to the sealing arm, it is
because there was not enough cooling time. Keep
the arm down for a longer period of time after the
light turns off.
FOR FURTHER ASSISTANCE, PLEASE CALL ULINE CUSTOMER
SERVICE AT 1-800-295-5510.

Other manuals for U-Line H-1029

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the U-Line H-1029 and is the answer not in the manual?

U-Line H-1029 Specifications

General IconGeneral
BrandU-Line
ModelH-1029
CategoryFood Saver
LanguageEnglish

Related product manuals