PAGE 4 OF 30 1119 IH -1114
UNIT WEIGHT PRESET DUAL FUNCTION PRIORITY
You can set the UNIT WEIGHT PRESET key to treat either of
its functions (unit weight presets or switch from lb to kg)
to operate as the default function.
0 = Quick press of UNIT WEIGHT PRESET key
operates "kg/lb" (default). Press and hold
UNIT WEIGHT PRESET for three seconds to
operate the unit weight presets function.
1 = Quick press of UNIT WEIGHT PRESET key
operates unit weight presets function (default).
Press and hold UNIT WEIGHT PRESET for three
seconds to operate "kg/lb."
1. Press ZERO, then 1, 6.
2. Press 0 or 1 to select the desired mode.
3. Press
.
to exit and save the settings.
ACCUMULATION SETUP
Set the way the scale shows or indicates totalized values.
0 = After pressing M+, display shows
totalized value. After three seconds, scale
counts back to zero.
1 = After pressing M+, display shows totalized
value. Press CE, scale counts back to zero.
2 = After pressing M+, beeper sounds,
display does not show totalized value.
1. Press ZERO, then 1, 1.
2. Press 0, 1 or 2 to select the desired mode.
3. You can set the way the M+ operates.
0 = M+ works only when weight is stable.
1 = M+ works even when weight is unstable.
1. Press ZERO, then 1, 4.
2. Press 0 or 1 to select the desired mode.
3. Press
.
to exit and save the settings.
Continuous/Zero
You can set M+ to operate continuously or only after the
scale returns to zero.
0 = After pressing M+, scale must return to zero
before M+ works again.
1 = After pressing M+, it’s ready to go again
immediately.
1. Press ZERO, then 1, 5.
2. Press 0 or 1 to select the desired mode.
3. Press
.
to exit and save the settings.
SETTING FUNCTION MODES CONTINUED
NETNET
→ 0←
WEIGHT UNIT WEIGHT QUANTITY
SMPL
WT
PC
WT
M+
STABLE
Pcs
X
USEr nnPLU
NETNET
→ 0←
WEIGHT UNIT WEIGHT QUANTITY
SMPL
WT
PC
WT
M+
STABLE
Pcs
X
USEr UnPS
NETNET
→ 0←
WEIGHT UNIT WEIGHT QUANTITY
SMPL
WT
PC
WT
M+
STABLE
Pcs
X
USEr nnPtP
NETNET
→ 0←
WEIGHT UNIT WEIGHT QUANTITY
SMPL
WT
PC
WT
M+
STABLE
Pcs
X
USEr nnP60