PAGE 1 OF 33 0819 IH-5819
DELUXE
COUNTING SCALE
1-800-295-5510
uline.com
π
H-5819, H-5820
H-5821, H-5822
DISPLAY DEFINITIONS
# NAME DESCRIPTION
1 DISPLAY
Displays the total weight, unit weight and
number of counted items.
2
Battery indicator. Indicates battery is low and
needs to be recharged.
3 STABLE
Stable indicator. Indicates the scale weight is
stable.
4 RECHARGE
Charging indicator. Indicates the battery
charging status.
5 ZERO Zero indicator. Indicates the scale is at zero.
6 GROSS
Gross indicator. Indicates scale is displaying
the gross weight.
7 NET
Net indicator. Indicates scale is displaying the
net weight.
8 HI / OK / LOW
Limits indicator. Indicates the High-Low limits in
weighing and counting.
9 M+
Accumulation indicator. Indicates the scale is
in the accumulation mode.
10
LB / OZ / G / KG
Weighing unit indicator. Indicates current
weighing unit.
11 AUTO
Automatic accumulation indicator. Indicates
the scale is in automatic accumulation mode.
12 PCS
Counting indicator. Indicates the scale is in
the counting mode.
OVERVIEW OF CONTROLS
KEYPAD DEFINITIONS
# NAME DESCRIPTION
1 ZERO Zero key. Used to clear and zero the display.
2 SAMPLE SIZE
Sample size key. Used when keying in the
sample amount.
3 COUNT
Count key. Used to enter the counting operation.
4 PRINT Print key. Used to send data to a printer or PC.
5 MODE
Mode key. Used to select the application
mode – weighing, counting, check weighing,
check counting or accumulation.
6 TARE
Tare key. Used to zero out the weight of a
container being used to hold small parts.
7 SET U. WT
Set Unit Weight key. Used to manually key in
the unit weight.
8 U / N / G
Unit / Net / Gross Weight key. Used to show the
unit, net or gross weight.
9 PLU
Unit Weight Memory key. Used to store weights
into scale memory.
10 UNITS Units key. Used to change weighing unit.
11 M+
Memory key. Used to add current weight or
count to memory.
12 MR / HI
Memory Recall key. Used to show total
accumulated weights or counts in memory.
HI key. Used to set high limit.
13 MC / LO
Memory Clear key. Used to clear
accumulated weights or counts from memory.
LO key. Used to set low limit.
14 C
Clear key. Used to clear incorrect numeric values.
15
Decimal key. Used to enter decimal place
when values are entered manually.
16 0-9 Numeric keys. Used to enter values manually.
1 16
14
15
2
3
4
5
8
6
109
11 12 13
7
7
8
9
4
5
6
1
2
3
0
C
Recharge
HI
OK LOW
2 3 4
1
5 6 7 8
12
11
10
9
DISPLAY KEYPAD
Para Español, vea páginas 12-22.
Pour le français, consulter les pages 23-33.

Questions and Answers

  • R
    Richard RussellAug 7, 2025
    Why does my U-Line H-5821 Scales say Load Hi?
    • M
      melissalittleAug 7, 2025
      If your U-Line Scales are displaying 'Load Hi', it indicates that the calibration weight used was too heavy. Ensure you use a calibration weight that is equal to or less than the maximum calibration weight to resolve this issue.
  • E
    Erin GonzalesAug 12, 2025
    What does Load Lo mean on my U-Line H-5821?
    • M
      Mark HardyAug 12, 2025
      If your U-Line Scales show 'Load Lo', it means the calibration weight you used is too light. Use a calibration weight that is equal to or exceeds the minimum calibration weight.
  • C
    comptondeanAug 17, 2025
    What to do if my U-Line H-5821 Scales display shows -OL-?
    • J
      Jennifer MillerAug 17, 2025
      If your U-Line Scales display shows '-OL-', it means the maximum weight capacity has been exceeded. To resolve this, simply remove some of the load from the platform.
  • T
    Thomas MitchellAug 22, 2025
    What to do if my U-Line Scales display FAIL?
    • X
      xruizAug 22, 2025
      If your U-Line Scales display 'FAIL', it indicates that the calibration process was unsuccessful. You should recalibrate the scale to fix this problem.
  • I
    Isabella ShawAug 27, 2025
    What to do if my U-Line Scales display Err 4?
    • A
      Ashley MeyerAug 27, 2025
      If your U-Line Scales display 'Err 4', this means the scale requires recalibration. Recalibrate the scale to resolve this issue.
  • B
    billyjohnsonSep 2, 2025
    How to fix a blinking display on U-Line H-5821?
    • M
      Megan DanielsSep 2, 2025
      If your U-Line Scales display is blinking, faded, or shows 'Bat lo', it indicates that the battery is low. To fix this, recharge the battery.

Summary

Overview of Controls

Display

Defines the various indicators and segments shown on the scale's display screen.

Keypad

Identifies and describes the function of each key on the scale's keypad.

Setup

Selecting the Location

Provides guidelines for choosing a stable and suitable environment for the scale.

Installing the Platform

Details the process of placing the scale platform correctly.

Leveling

Explains how to ensure the scale is properly balanced using its level indicator.

Connecting Power

Describes how to connect the scale to AC power or utilize its battery.

Operation

Calibration

Steps for calibrating the scale for accurate measurements.

Operation Continued

Weighing

Mode for performing standard weight measurements.

Counting

Mode for counting a number of uniform weight items.

Troubleshooting

U-Line H-5821 Specifications