EasyManua.ls Logo

Ulma MK Structure - Page 18

Default Icon
63 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Construcción
ConstrucciónConstrucción
Construcción
18
MK
MK MK
MK STRUCTURE
STRUCTURESTRUCTURE
STRUCTURE
2.2.3. NODE 120 MK
This node enables to connect up to 3 walers at 60º.
The connections are fastened with 6 bolts M16
inserted into the D17 holes.
The D20 holes are mainly used for the connection of
secondary components, i.e., bracing items.
Moreover, another (male) item can be connected to
the node centre in a hinged way pointing
downwards. The connection is fastened with pins
D40.
2.2.4. NODE 60 F MK AND NODE 60 M MK
These nodes enable to connect up to 2 walers at 60º.
The connections are fastened with 6 bolts M16
inserted into the D17 holes.
The D20 holes are mainly used for the connection of
secondary components, i.e., bracing items.
There are two node types: a female (F) and a male
(M). Both enable to connect another item (male or
female) to the node centre in in a hinged way with
pins D40.
2.2.5. AXIAL NODE M D40 MK AND AXIAL NODE
90º M D40 MK
Both nodes enable to connect any waler to an
already assembled structure in a hinged way. The
connections are fastened with 6 bolts M16 inserted
into the D17 holes. These nodes provide high load-
bearing capacity.
They are male nodes connected to a female node of
the structure with pins D40.
2.2.6. NODE 360 MK
This node enables to connect up to 6 walers. The
connections are fastened with 6 bolts M16 inserted
into the D17 holes. Two of the six walers are
connected lengthwise with a remaining gap of 375
mm between their respective ends.