EasyManua.ls Logo

UltraFire UBS1RF - Maintenance

UltraFire UBS1RF
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
It may be necessary to remove an alarm from the network in some situations, for
example if troubleshooting an alarm that does not respond to the test signal.
1. Turn the alarm head anti-clockwise and remove it from the baseplate.
2. Take the batteries out from the battery compartment.
3. Press and hold the test button while reinserting the batteries. If successful,
the red LED will turn on for about 3 seconds, otherwise repeat accordingly.
4. Once the LED turns o󰀨, release the test button.
5. Press and release the test button again when the LED turns back on.
6. The LED will turn o󰀨 and the alarm will chirp, indicating success.
7. The alarm is now in standby operation as a standalone unit, no longer
interlinked with any other alarms.
Clear Interlink Code
Test your alarms to ensure proper operation once per week by pressing the test
button. If there is no sound output it means that the alarm is faulty, the batteries
are at, or that the installation procedure may not have been followed correctly.
Please try replacing the batteries and reinstalling the alarm head. If the alarm still
fails to react to the test button, please read the Troubleshooting section of this
manual.
Testing
Maintenance

Related product manuals