ADVANCED CALLING • 15
Setting the Baudot code baud rate +
Each time you turn on the Minicom IV, the Baudot code baud rate
is set to the auto setting. This setting uses whichever code is need-
ed to answer a call by detecting what code the other TTY is using.
If you need to specify the code that the Minicom IV uses, you can
set it so that it will only use either 45.5-baud or 50-baud Baudot
code. When you do, the Minicom IV will not try to use other
codes. Follow these steps to change the Baudot code baud
rate setting:
1.Press the options key ( + ). You will see PRINT (UP/LOW)
CASE on the display.
2.Press the key until you see BAUDOT (AUTO) BAUD on
the display.
3.Press the to choose one of the following:
• AUTO to automatically use either 45.5 baud Baudot code or
Turbo Code.
• 45 to use only 45.5-baud Baudot code. Most Baudot TTYs use 45.
•
50 to use only 50-baud Baudot code. TTYs purchased in
Australia,
New Zealand, and South Africa use 50-baud Baudot
code.
Note: In order to use 50-baud Baudot code, you must change the
setting to 50. The Auto setting does not use 50-baud Baudot code.
4.Press the key to save the new setting and leave options or
press the key to save and go to the next option.
The Baudot code baud rate setting always returns to auto when
you turn off the Minicom IV.