138
RK20: Remote Start/Keyless Entry System
continued
Factory default settings are indicated in
bold
in the following feature tables.
MENU #2
Feature Default LED ON Setting LED OFF Setting
Number (Press "LOCK" Button) (Press "UNLOCK" Button)
1
Intelli-Tach (1)
Voltage (2), OFF (3), Tachometer (4)
2
12 Minute Run Time (1)
24 Minutes (2), 60 Minutes (3) Run Time
3
Constant Parking Light Output
Flashing Parking Light Output
4
Cranking Time 0.6 sec. (1)
Crank Time: 0.8 (2), 1.0 (3), 1.2 (4), 1.4 (5)
1.6 (6), 1.8 (7), 2.0 (8), 4.0 (9) Seconds
5 Activation Pulse: 1 (1)
Activation Pulses: 2 (2)
, 3 (3)
6
2nd Ignition Output
2nd Accessory Output
7
Acc. State During Wait to Start OFF
Acc. State During Wait to Start ON
8
2nd Status Output Normal
Rear Defogger Latched (2), Rear Defogger
Pulse (3)
9
Anti-Grind ON
Anti-Grind OFF
10
Wait to Start Timer: 0 sec (1)
15 (2), 30 (3), 45 (3) seconds
S100/S400: Security/Keyless Entry System
Factory default settings are indicated in
bold
in the following feature tables.
MENU #1
Feature Default LED ON Setting LED OFF Setting
Number (Press "LOCK" Button) (Press "UNLOCK" Button)
1
Active Arming
Passive Arming
2
Chirps ON
Chirps OFF
3
Ignition Controlled Door Locks ON
Ignition Control Door Locks OFF
4
Active Locking OFF
Passive Locking ON
5
Panic with Ignition ON
No Panic with Ignition ON
6
0.8 Second Door Lock Pulse
3.5 Second Door Lock Pulse
7
Forced Passive Arming ON
Forced Passive Arming OFF
8 Automatic Engine Disable ON
Automatic Engine Disable OFF
9
Armed When Driving
Anti-Carjacking System
10
Anti-Code Grabbing ON
Anti-Code Grabbing OFF
Factory default settings are indicated in
bold
in the following feature tables.
MENU #2
Feature Default LED ON Setting LED OFF Setting
Number (Press "LOCK" Button) (Press "UNLOCK" Button)
1
Siren
Horn Honk
2
30-Second Siren Duration
60-Second Siren Duration
3
False Alarm Prevention Circuitry ON
False Alarm Prevention Circuitry OFF
4
Progress Door Trigger
Instant Door Trigger
5
Override Switch Input: 1 Pulse
Override Switch Input: 2-5 Pulses
6
Open Zone Bypass Notice: ON
Open Zone Bypass Notice: OFF
7
Ignition Controlled Dome Light ON
Ignition Controlled Dome Light OFF
8
Single Unlock Pulse
Double Unlock Pulse
9
Channel 3: Validity
Channel 3: Latched/Latched (2), Reset with
ignition(3), 30-Second Timed (4), Second
Unlock Output (5)
* NOTE: The numbers in parentheses indicate the number of times the LED will flash.