SR1000: Remote Start/Security/Keyless Entry System
Factory default settings are indicated in
bold
in the following feature tables.
MENU #1
Feature Default LED ON Setting LED OFF Setting
Number (Press "LOCK" Button) (Press "UNLOCK" Button)
1
Active Arming
Passive Arming
2
Chirps ON
Chirps OFF
3
Ignition Locks ON
Ignition Locks OFF
4
Ignition Unlock ON
Ignition Unlock OFF
5
Active Locking Only
Passive Locking
6
Panic With Ignition ON
No Panic With Ignition
7
0.8 Second Door Lock Pulse
3.5 Second Door Lock Pulse
8
Forced Passive Arming ON
Forced Passive Arming OFF
9 Automatic Engine Disable ON
Automatic Engine Disable OFF
10
Armed While Driving ON
Armed While Driving OFF
11
Anti-Code Grabbing ON
Anti-Code Grabbing OFF
MENU #2
Feature Default LED ON Setting LED OFF Setting
Number (Press "LOCK" Button) (Press "UNLOCK" Button)
1
Siren Output Constant
Siren Output Pulsed
2
30-Second Siren Duration
60-Second Siren Duration
3
False Alarm Prevention Circuitry ON
False Alarm Prevention Circuitry OFF
4
Progress Door Trigger
Instant Door Trigger
5
Override Switch Input: 1 Pulse
Override Switch Input: 2-5 Pulses
6
Open Zone Bypass Notice: ON
Open Zone Bypass Notice: OFF
7
Ignition Controlled Dome Light ON
Ignition Controlled Dome Light OFF
8
Single Unlock Pulse
Double Unlock Pulse
9
Factory Disarm with Channel 2 ON
Factory Disarm with Channel 2 OFF
10
Channel 4 Validity
Channel 4: Latched/Latched (2), Reset with
Ignition (3), 30-Sec. Timed (4), 60-Sec.
Timed (5), 90-Sec. Timed (6)
11
Channel 5 Validity
Channel 5: Latched/Latched (2), Reset with
Ignition (3), 30-Sec. Timed (4), 60-Sec.
Timed (5), 90-Sec. Timed (6)
* NOTE: The numbers in parentheses indicate the number of times the LED will flash.
MENU #3
Feature Default LED ON Setting LED OFF Setting
Number (Press "LOCK" Button) (Press "UNLOCK" Button)
1
Engine Checking ON
Engine Checking OFF
2
Engine Checking Tach
Engine Checking Voltage
3
Run Time: 12 Minutes (1)
Run Time: 24 Min (2), 60 Min. (3)
4
Parking Lights Flashing
Parking Lights Constant
5
Crank Time: 0.6 Sec (1)
0.8 (2), 1.0 (3), 1.2 (4), 1.4 (5), 1.6 (6),
1.8 (7), 2.0 (8), 4.0 (9)
6
Voltage Check: High
Voltage Check: Low
7
Short Run/Turbo Timer: 1 Min (1)
3 (2), 5 (3), 10 (4) Minutes
8 Activation Pulse Count: 1 (1)
Activation Pulse Count: 2 (2)
9
2nd Ign/ACC Output: Ignition
Accessory
10
Factory Disarm with Channel 2 ON
Factory Disarm with Channel 2 OFF
11
2nd Status Output: Normal
Rear Defogger: Latched 10 Min (2),
Pulsed (3)
12
Anti-Grind: ON
Anti-Grind: OFF
* NOTE: The numbers in parentheses indicate the number of times the LED will flash.