SR9000: 2-Way Remote Start/Security/Keyless Entry System
(continued)
MENU #2
Feature Default LED ON Setting LED OFF Setting
Number (Press "LOCK" Button) (Press "UNLOCK" Button)
1
30-Second Siren Duration
60-Second Siren Duration
2
False Alarm Prevention Circuitry ON
False Alarm Prevention Circuitry OFF
3
Progress Door Trigger
Instant Door Trigger
4
Override Switch Input: 1 Pulse
Override Switch Input: 2-5 Pulses
5
Door Trigger Error Chirp ON
Door Trigger Error Chirp OFF
6
Ignition Controlled Dome Light ON
Ignition Controlled Dome Light OFF
7
Single Unlock Pulse
Double Unlock Pulse
8
Single Lock Pulse
Double Lock Pulse
9
Factory Disarm with Channel 2 ON
Factory Disarm with Channel 2 OFF
10
Factory Alarm Disarm with Unlock (1)
Before Unlock (2), Remote Start Only (3)
11
Factory Alarm Disarm 1 Pulse
2 Pulses
12
Auxiliary 1 Validity (1)
Latched (2), Latch Reset with Ignition (3),
30-Sec. Timed (4)
13
Auxiliary 1 Linking None (1)
Arm (2), Disarm (3), Remote Start (4)
14
Auxiliary 2 Validity (1)
Latched (2), Latch Reset with Ignition (3),
30-Sec. Timed (4)
15
Auxiliary 2 Linking None (1)
Arm (2), Disarm (3), Remote Start (4)
16
Auxiliary 3 Validity (1)
Latched (2), Latch Reset with Ignition (3),
30-Sec. Timed (4)
17
Auxiliary 3 Linking None (1)
Arm (2), Disarm (3), Remote Start (4)
* NOTE: The numbers in parentheses indicate the number of times the LED will flash.
Factory default settings are indicated in
bold
in the following feature tables.
MENU #3
Feature Default LED ON Setting LED OFF Setting
Number (Press "LOCK" Button) (Press "UNLOCK" Button)
1
Engine Checking ON
Engine Checking OFF
2
Engine Checking Tach
Engine Checking Voltage
3
Run Time: 12 Min. (1)
Run Time: 24 (2), 60 (3) Min.
4
Parking Lights Flashing
Parking Lights Constant
5
Crank Time: 0.6 sec. (1)
0.8 (2), 1.0 (3), 1.2 (4), 1.4 (5), 1.6 (6),
1.8 (7), 2.0 (8), 4.0 (9)
6
Voltage Checking: High
Voltage Checking: Low
7
Short Run/Turbo: 1 Min. (1)
3 (2), 5 (3), 10 (4) Minutes
8 Activation Pulse Count 1 (1)
Activation Pulse Count 2 (2)
9
2nd Ign/Acc Output: Ignition
Accessory
10
Acc. State During Wait-to-Start: OFF
ON
11
2nd Status Output: Normal (1)
Rear Defogger: Latched 10 Min. (2)
Pulse (3)
12
Anti-Grind: ON
Anti-Grind: OFF
13
Diesel Timer Wait-to-Start Input (1)
Timed 15 (2), 30 (3), 45 (4) Seconds
14
Timer Mode- Timed Starts
Temperature Starts
15
Run Time: 12 Min. (1)
3 (2), 6 (3), 9 (4) Minutes
* NOTE: The numbers in parentheses indicate the number of times the LED will flash.