EasyManua.ls Logo

UNI-T UT603 - Continuity & Diodes Accuracy; Capacitance Test Accuracy (UT603)

UNI-T UT603
26 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Diode:
Open Circuit Voltage around 5.8V, forward current around
1mA.
Continuity
10 , beeper comes on continuously.
> 10 , beeper may or may not comes on.
l
l
Overload Protection
0.315A, 250V, fast type fuse, 5x20 mm
Measure of Capacitance:
1F=10
3
mF = 10
6
µF= 10
9
nF = 10
12
pF
Discharge all high-voltage capacitors before testing
capacitance.
The tested value of 2nF range needs to minus open
circuit value.
l
l
l
l
21
Model UT602/603: OPERATING MANUAL
B. Continuity & Diodes
Range Resolution
Overload
Protection
Function
Diode
Continuity
1mV
1
250V rms
Remarks:
C. Capacitance Test (UT603 only)
Range Resolution Accuracy
Testing Frequ-
ency / Voltage
2.000nF
20.00nF
200.0nF
2.000µF
20.00µF
200.0µF
600µF
0.001nF
0.01nF
0.1nF
0.001µF
0.01µF
0.1µF
0.001mF
(1%+5)
(4%+5)
Reference only
1kHz/150mV
100Hz/15mV
100Hz/1.5mV
Remarks: