11
2 Cups electronic box (d2 type)
Use of the doses to be programmed
- 4 coffee doses and 1 manual function, Continu/Stop are available.
During the infusion, it is displayed :
* 1c or 2c = 1 or 2 small cups
* 1C or 2C = 1 or 2 large cups
* C- = Continu/Stop
- At any time you can change the selection by pressing another key.
- The dosage is automatic but the infusion can be stopped manually by pressing the key
Continu/Stop.
- Programing: The multiple doses being computed, only two programing are necessary (1c or 2c)
and (1C or 2C).
Configuration parameters
* dn / dt For the automatic calculation of the multiple doses
dn = normal dosage
dt = dosage with "Torino" kit
* C0 / C1 Chronometer for the infusion time
C0 = no chronometer
C1 = display of the infusion time
* A0 / A1 Authorization to program
A0 = prohibited programing
A1 = authorized programing
After switching on, the display shows the following information in order:
- The version number of the electronic memory: ex. r1
- The type of box: d2
- The active functioning parameters: ex. dn, CO, A1
Modification of the configuration parameters
- Switch the machine off (switcher 0/1)
- Press simultaneously both keys P1 and P4, and in the same time, switch again the machine on
- Press the key P4 to change the selection (ex. dn or dt)
- Press the key P5 to change function (ex. dosage dn/dt or Chrono: C0/C1)
- Switch off to leave the configuration mode or wait the automatic leaving at the end of 10s.
Continu / Stop key