21
Instructions for the installer
Type C33
The maximum allowable length of the vertical concentric pi-
pes (Ø 80/125) is of 8,5 metres flue terminal included
(Ø 80/
125); for each elbow added the maximum length permitted
has to be reduced by 1 metre.
FLUE OUTLETS WITH CONCENTRIC DUCTS Ø 80/125 mm
Important: the outlet/inlet flue has to
have a minimum inclination of 3%
towards the top in the outlet direction,
so as to enable the collection of any
condensate formed in the boiler.
pendenza 3%
KIT5730C
KIT5820C
00361334
00360357
00361256
00361334
220
257 (24 kW)
242 (35 kW)
372