EasyManuals Logo

Unical KON 1 C24 User Manual

Unical KON 1 C24
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #16 background imageLoading...
Page #16 background image
16
KON 1 C24 KON 1 C28 KON 1 C35
Appliance category
II
2H3P
II
2H3P
II
2H3P
Minimum heat. circuit output (∆t 20 °C) l/min
2,1 3,1 3,1
Minimum heating circuit pressure bar
0,5 0,5 0,5
Maximum heating circuit pressure bar
3 3 3
Primary circuit content l
2,2 2,8 2,8
Maximum operating temperature in heat. °C
85 85 85
Minimum operating temperature in heat. °C
30 30 30
Expansion vessel total capacity l
7 10 10
Expansion vessel pre-load bar
1 1 1
Maximum system capacity (max temp. calc.) l
144 205 205
Minimum domestic hot water circuit ow rate l/min.
2,0 2 2,0
Minimum domestic hot water circuit pressure bar
0,5 0,5 0,5
Maximum domestic hot water circuit pressure bar
6 6 6
Domestic hot water specic ow rate (∆t 30 °C) ‘‘D’’ l/min.
11,2 13 16
Domestic hot water ow rate limiter l/min.
- - -
Production of D.H.W. in continuous operation with ∆t 45 K
l/min.
7,34 8,6 10,1
Production of D.H.W. in continuous operation with ∆t 40 K
l/min.
8,26 9,7 11,4
Production of D.H.W. in continuous operation with ∆t 35 K
l/min.
9,44 11,1 13,0
Production of D.H.W. in continuous operation with ∆t 30 K
l/min.
11,0 12,9 15,2
Production of D.H.W. in continuous operation with ∆t 25 K (*)
l/min.
13,2 15,5 18,3
Voltage/Frequency electric power supply °C
38-60 38-60
38-60
Fuse on the power supply V-Hz
230/50 230/50 230/50
Maximum absorbed output A (F)
4 4 4
Protection rating IP
X5D X5D X5D
Net weight boiler kg
40 41 41
Gross weight boiler kg
43 44 44
F factor 1 2 2
R factor
(*) mixed
2.5 - GENERAL FEATURES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Unical KON 1 C24 and is the answer not in the manual?

Unical KON 1 C24 Specifications

General IconGeneral
BrandUnical
ModelKON 1 C24
CategoryBoiler
LanguageEnglish