EasyManua.ls Logo

Unitech MS912

Unitech MS912
14 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Unitech electronics co., ltd.
Version 1.0
5F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.)
Tel: + 886 2 89121122
Fax: +886 2 89121810
website: www.ute.com
MS912 Wireless Scanner
Quick Reference Guide
DATA FORMAT
. R011$
DATA FORMAT
The default Data Format is <Item No.>, <Date>, <Time>, <Barcode
Data> below are items and their setup codes:
Code Item Code Item
1 Item No. 3 Time
2 Date 4 Barcode Data
Example:
To change Data Format to <Item No.>, <Barcode Data>, <Date>,
<Time>
1. Scan [Data Format]
2. Scan [1], [4], [2], [3] on page 9.
3. Scan [Data Format]
. R011$
FIELD SEPARATOR
Default is comma ( , ) . You may replace it with any alphanumeric
characters from the full ASCII table in User’s Manual (on CD).
Example: To change Field Separator to Semicolon ( ; )
1. Scan [Field Separator]
2. Scan [ ; ] from the full ASCII table.
3. Scan [Field Separator]
DATE & TIME SETUP
SET DATE
. R006$
Example: To set Date to 2012-08-01 (Year-Month-Day):
1. Scan [Set Date]
2. Scan [1], [2], [0], [8], [0], [1] on page 9 & 10.
3. Scan [Set Date]
SET TIME
. R007$
Example: To set Time to 08:10:30 am (Hr:Min:Sec)
1. Scan [Set Time]
2. Scan [0], [8], [1], [0], [3], [0] on page 9 & 10.
3. Scan [Set Time]
* To avoid Time and Date being reset to factory default due to
running out of battery, please fully charge the scanner for
at least 3
hours before use.

Other manuals for Unitech MS912