- 59 -
Length Within Range - Select this option to decode a code within a specified
range. For example, to decode Codabar symbols containing between 4 and 12
characters, first scan Codabar Length Within Range, then scan 0, 4, 1 and 2
(single digit numbers must always be preceded by a leading zero). Numeric
bar codes begin on Appendix B. To change the selection or cancel an incorrect
entry, scan Cancel on Appendix B.
Any Length - Scan this option to decode Codabar symbols containing any
number of characters.
3.9.3 CLSI Editing
When enabled, this parameter strips the start and stop characters and inserts a
space after the first, fifth, and tenth characters of a 14-character Codabar
symbol.
NOTE Symbol length does not include start and stop characters.