sales@utplindia.in
+91 7046223333 , 9427301436
www.utplindia.in
www
UT-1401
DP INDICATOR AND SENSOR
3
Flame Proof
High scale / Low scale
Full range as per input selection
Other
Mounting
Bricks and modules wall flush panel mounting
MOC
Full S S 316 plate and box , back side wall mounting M S covers.
Power Consumption
24 VDC @ 4 Watt Maximum
Input
Indication
DP
Channel - 1 : 3 digit seven segment 0.56" Red display.
Accuracy
DP
1% on FS in Allunit
Response Time
1 Second
1 Nos (DP)
Nos Of Input
Integral Or Remote (external)
Temperatures Input
DP Input
24V/5V DC @ 30mA max, Isolated from Input & Output
Transmitter Power Supply
Status indication
LEDs for Relay status & Communication
Prog. parameters
Modbus RTU RS- 485/RS- 232 Communication
Baud rate, Parity, Node address, Stop bit
Protocols & method
Max. Connections
Communication
Up to 128 Units
Programmable
Parameters
Setpoint / Hysteresis
Alarm Logic
Full range as per input selection
F.S. high & low alarm
Gas Group
I IIA IIB as per IS 2148/1981
TECHNICAL SPECIFICATIONS
2.3 Technical Specifications
Integral Or Remote (external)
Range
DP
-10 to 10 mm / -25 to 25 mm / -100 to 100 mm / -200 to 200 mm ......
Display Resolution
mmWc : 0.1 / PA : 1 / Hpa : 0.01
Read/Write
Read : Process Value, Decimal Point. Write : Hi Low set point.
Operating Ambient
Temp. : 0~50˚C, Humidity : Below 90% Non condensing
Endose Certificate
Enclosure is certifies by C.M.R.I. dhanbad
Display Glass
Clear glass thognet type A as per is 2206
Degree Protection
Ip65 as per IS 2147
Material Of Construction
Aluminium Alloy
Cable Entry
2 X 3/4 “ ET
FDA 21 CFR Part 11 - GAMP - 4 compatible
Microcontroller based indicator wit hinbuilt Temperature & DP measurement in single enclosure.
Incorporates highly stable built-in or DP sensor. (with different unit like mmWc / pa / kpa / mmhg).
3 digit, 0.56" bright LED display for displaying DP.
Process parameter HI and LOW LEDs. Status indicator for one channel.
User selectable set limits for process value violation.
Inbuilt buzzer to audible process value violation.
Password protection for calibration and programming mode.
Software based Calibration.
MODBUS RTU multi drop RS-485 serial communication for PLC, SCADA, etc.
Programmable device address, baud rate, (max no. of device is 1-256).
Remote programmable from master device.
User programmable offset correction.
*
*
*
*
*
*
*
*
*
*
*
*
*
FEATURES
Compact, All stainless steel of FLP enclosure with 35 mm depth for installation in prefab panels.
Brick and modular wall mounting and flush mounting.
*
*
*
*
FDA21 CFR part 11 compliance data logging software available.
Ex. Flameproof model available for Hazardous applications.