POSITIONING
Installation area requirements
08
Install the appliance in areas:
designated to, and adequate for, industrial food cooking
that are adequately ventilated
that comply with the laws in your country regarding system safety/
safety in the workplace
protected from the weather
at a temperature of between +5°C and +35°C (41°F and 104°F)
with humidity below 70%.
The law requires gas appliances to be installed in areas:
with an adequate surface area and ventilation for the sum of the
gas supplies for the installed appliances
prepared for evacuating external flue gases . For further informa-
tion, see the section “Gas connection (gas ovens only)” on page
38.
Requirements for flooring and substructures
09
The floor beneath the appliances must be:
stable and perfectly level
level and even
NOT flammable
fireproof
NOT heat-sensitive
able to support the appliance weight at full load without deforming
or experiencing structural failure.
If the appliances are to be rested on customers’ own substructures,
these substructures must meet the same requirements as listed for
the flooring. Substructures must also:
NOT be movable
be suitably sized for the appliance requiring support
.
UNOX stands and cabinets meet all requirements.