86 CHAPTER 6: TECHNICAL REFERENCE
Table6-7 Settings for S32
Bit Value Results
0 1 V.8 Call Indicate enabled.
1 2 Enables V.8 mode.
2 4 Reserved.
3 8 Disable V.34 modulation.
4 16 Disable V.34+
modulation.
5 32 Disable x2 modulation.
6 64 Disable V.90 modulation.
7 128 Disable V.92 Modulation
Table6-8 Settings for S33
Bit Value Results
0 1 Disable 2400 symbol rate.
1 2 Disable 2743 symbol rate.
2 4 Disable 2800 symbol rate.
3 8 Disable 3000 symbol rate.
4 16 Disable 3200 symbol rate.
5 32 Disable 3429 symbol rate.
6 64 Reserved
7 128 Disable shaping.
Table6-9 Settings for S41
Bit Value Results
0 1 Distinctive ring enabled.
1 2 Speakerphone connect message
override (voice products only).
2 4 Disable Digital Line Guard (56K
internal faxmodems only).
3 8 Message waiting (voice products only).

Table of Contents