6.2. Device programming
If no button is pressed during 1 minute, controller will exit programming mode and the keyboard will be locked.
Unlock the keyboard by pressing and holding for 5 seconds.
Press SEL button to enter the menu:
Set clock - setting the current time,
Set regen time - setting the time of regeneration start,
Set water hardness - setting input water hardness in mg / l (ppm).
A table for converting ° dH to mg / l (ppm) is on the control head and below:
°dH
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
mg/l (ppm)
179
197
214
232
250
268
286
304
322
340
357
375
393
411
429
447
464
482
500
518
536
6.2.1 . Setting CURRENT TIME
Unlock the controller by holding buttons for 5 seconds
Press SEL button to enter the soener parameters, Set clock parameter
is highlighted on the display
Press SEL button to enter the clock setting, hours start flashing
Use
buttons to set the hour
Confirm with SEL button, minutes start flashing
Use buttons to set the minutes
Press SEL button to save changes
Use key to go to the next parameter
6.2.2. Setting REGENERATION TIME
Regeneration start time aer set flow is programmed at 2:00 a.m. by default.
We recommend leaving this value unchanged.
To change regeneration time:
Unlock the controller by holding buttons for 5 seconds
Press SEL button to enter the soener parameters, Set regen time parameter is highlighted on the display
Press SEL button to enter the parameter, hours start flashing
Use buttons to set the hour
Confirm with SEL button, minutes start flashing
Use buttons to set the minutes
Press SEL button to save changes
Use key to go to the next parameter
6.2.3. INPUT WATER HARDNESS setting
Unlock the controller by holding
Press SEL button to enter the soener parameters, using the arrows set the Input hardness parameter
Press SEL button, the first value starts flashing
Using the buttons set the appropriate hardness value
Confirm with SEL, the second value starts flashing
Using the buttons set the appropriate hardness value
Confirm with SEL, the third value starts flashing
Using the buttons set the appropriate hardness value
Press the SEL button to save changes
The head automatically calculates the amount of water to be treated.