g. When the require high weight limit attained, press
and hold ON/ZERO, then press TARE
h. The LO INDICATOR appears and the cursor is flashing,
scale is now in lower weight limit setup
i. Utilize MODE, TARE and ON/ZERO to set the required
low weight limit
j. When the require low weight limit attained, press
and hold ON/ZERO, then press TARE
k. Scale displays buzzer warning parameter setup
l. Press MODE until the desired buzzer output parameter
appears
NOTE:
-bb_L. = buzzer warning when weight detected
below the low weight limit set.
-bb_no = no buzzer warning.
-bb_S. = buzzer warning when weight detected within
the high and low weight limit set.
-bb_H.L. = buzzer warning when weight detected
below/above the low/high weight limit set.
-bb_H. = buzzer warning when weight detected above
the high weight limit set.
m. When the require buzzer warning setting is selected,
press and hold ON/ZERO, then press TARE to return
to normal operation status