SWITCH 10: PROGRAMMING OF THE LEVEL
OF TEMPERATURE
The temperature can be set on 5 levels, under which the sun
sensor must not open the awning, even if the light intensity has
exceeded the level set by switch 8
This function is particularly useful in Countries with wintry
weather, where sunny but very cold days are frequent. In this case,
it is not necessary to open the awnings, to let the sun warm the
inner rooms.
To set the level of temperature it is necessary to use a
remote control previously stored and proceed as follows:
1. Multichannel transmiter only: press several times the button
SELC of the transmitter until shown by leds the channel
stored.
2. Position the roll-up shutter at the mid-height
3. Set on ON the switch 10 of the transmitter.
4. Press and keep pressed (for 5 about seconds) the button PROG
of the transmitter until the motor moves jerkily in both the
ways showing that it enters the storing.
5. The number of jerks made by the motor corresponds to the
level currently set:
1 jerk = level 1 = sensor disabled (default)
2 jerks = level 2 = 0°C
3 jerks = level 3 = 5°C
4 jerks = level 4 = 10°C
5 jerks = level 5 = 15°C
6. To increase the level press button UP, to decrease it press
button DOWN.
7. As soon as the control unit receives the control, it shows the
new level moving the motor with the corresponding number
of jerks.
8. To exit the programming press STOP: the motor displays again
the set level and exits.
9. Set on OFF the switch 10