- 59 -
PARAMETER VALUE SUBMENU DESCRIPTION DEFAULT CHAPTER MEMO
ING1
Input 1 set up
START
16
START
Startcycle(N.O.contact)
NO
Nofunction
CHIU
Alwaysclose(N.O.contact)
APRE
Alwaysopen(N.O.contact)
STOP
Stop(N.C.contact)
ST.PE
Partialopen(N.O.contact)
ING2
Input 2 set up
ST.PE
16
ST.PE
Partialopen(N.O.contact)
START
Startcycle(N.O.contact)
NO
Nofunction
CHIU
Alwaysclose(N.O.contact)
APRE
Alwaysopen(N.O.contact)
STOP
Stop(N.C.contact)
ING3
Input 3 set up
NO
16
NO
Nofunction
PRES
Forcedeadmanmode(N.O.contact)
STOP
Stop(N.C.contact)
ST.PE
Partialopen(N.O.contact)
START
Startcycle(N.O.contact)
RX
Receiver mode
START
17
START
Channel1=START
Channel2=PARTIALSTART
APCH
Channel1=OPEN
Channel2=CLOSE
STOP
Stop command function
PROS
16
PROS
Stopthenresume
CHIU
Closethenhold
APRE
Openthenhold
INVE
Stoptheninvert
FOT1
Photocell 1 mode
NO
11
NO
Nofunction
APCH
Enabledinopeningandclosing
FOT2
Photocell 2 mode
CFCH
11
CFCH
Enabledwithgateclosedandduringclosing
phase
CH
Enabledclosingphase
NO
Nofunction