EasyManua.ls Logo

Vacon NXL series User Manual

Vacon NXL series
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
AT LEAST THE 11 FOLLOWING STEPS OF THE
START-UP QUICK GUIDE
MUST BE PERFORMED
DURING THE INSTALLATION AND COMMISSIONING.
IF ANY PROBLEMS OCCUR, PLEASE CONTACT YOUR LOCAL DISTRIBUTOR.
Start-up Quick Guide
1. Check that the delivery corresponds to your order, see Chapter 3.
2. Before taking any commissioning actions read carefully the safety instructions in
Chapter 1.
3. Before the mechanical installation, check the minimum clearances around the unit and
check the ambient conditions in Chapter 5.
4. Check the size of the motor cable, mains cable, mains fuses and check the cable
connections, read Chapter 6.
5. Follow the installation instructions, see Chapter 5.
6. Control cable sizes and the grounding system are explained in Chapter 6.1.1.
7. Instructions on using the keypad are given in Chapter 7.
8. All parameters have factory default values. In order to ensure proper operation, check
the rating plate data for the values below and the corresponding parameters of
parameter group P2.1. See Chapter 8.3.2.
nominal voltage of the motor, par. 2.1.6
nominal frequency of the motor, par. 2.1.7
nominal speed of the motor, par 2.1.8
nominal current of the motor, par. 2.1.9
motor power factor, cosϕ, par. 2.1.10
All parameters are explained in the Multi-Control Application Manual.
9. Follow the commissioning instructions, see Chapter 8.
10. The Vacon NXL Frequency Converter is now ready for use.
11. In the end of this manual, you will find a quick help with the default I/O, control panel
menus, monitoring values, fault codes and basic parameters
Vacon Plc is not responsible for the use of the frequency converters against
the instructions.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Vacon NXL series and is the answer not in the manual?

Vacon NXL series Specifications

General IconGeneral
Output Voltage0-Uinput
Power Range0.75 - 30 kW
Control MethodVector control, V/f control
EnclosureIP21
Communication OptionsModbus, Profibus, CANopen, Ethernet
Protection FeaturesOvercurrent, overvoltage, undervoltage, overtemperature, short circuit
Braking ChopperBuilt-in

Summary

Safety

Warnings

Important safety warnings for operating the frequency converter.

Safety Instructions

Guidelines for safe installation and handling of the converter.

Receipt of Delivery

Technical Data

Power Ratings and Dimensions

Detailed power ratings and physical dimensions for various models.

Installation Guide

Mounting Procedures

Instructions for physically mounting the frequency converter units.

Cabling and Connections

Power Connections

Diagrams and instructions for making power connections.

Control Keypad Operation

Start-up Wizard

Step-by-step guide to the automated start-up programming wizard.

Parameter Menu (P2)

How to access and edit parameter values.

Commissioning Procedures

Commissioning Safety Precautions

Essential safety directions and warnings before commissioning.

Frequency Converter Commissioning Steps

Step-by-step guide for commissioning the frequency converter.

Fault Tracing and Troubleshooting

Fault Tracing Overview

Explains fault detection, display, and reset procedures.

Fault Codes, Causes, and Corrections

Table of fault codes, their causes, and corrective actions.