For the installer
ecoTEC plus 612
ecoTEC plus 615
ecoTEC plus 618
ecoTEC plus 624
ecoTEC plus 630
ecoTEC plus 637
ecoTEC plus 824
ecoTEC plus 831
ecoTEC plus 837
ecoTEC pro 28
ecoTEC pro 24
Instructions for installation and servicing
ecoTEC
Wall hung room sealed fan assisted condensing boiler
GB

Table of Contents

Other manuals for Vaillant ecoTEC plus 615

Questions and Answers

  • C
    Cassandra RiveraAug 30, 2025
    What to do if the water pressure sensor or cable harness hydraulics are defective in my Vaillant ecoTEC plus 615?
    • V
      vhernandezAug 30, 2025
      If the water pressure sensor or cable harness hydraulics are defective in your Vaillant Boiler, it could be due to a broken line to the water pressure sensor, a short-circuit at 0 V, or a defective water pressure sensor. Inspect and replace the water pressure sensor or repair the line.
  • D
    donald74Aug 29, 2025
    Why is there a short circuit in the return-NTC of my Vaillant ecoTEC plus 615?
    • C
      chavezjodiAug 29, 2025
      A short circuit in the return-NTC of your Vaillant Boiler is often due to a defective NTC. Inspect and replace the NTC if defective.
  • K
    Kathleen GreeneAug 29, 2025
    What to do if there is a short circuit in the flow-NTC of my Vaillant ecoTEC plus 615?
    • B
      Brittany WhiteAug 29, 2025
      If there is a short circuit in the flow-NTC of your Vaillant Boiler, it could be due to the NTC plug shorted to the casing or a defective NTC. Inspect and replace the NTC if defective.
  • R
    Roberto FitzgeraldSep 12, 2025
    What does EEPROM error mean in my Vaillant Boiler?
    • E
      elizabeth81Sep 13, 2025
      An EEPROM error indicates that the electronics are defective. Replace the defective electronics.
  • B
    Brenda MorrisSep 16, 2025
    What to do if my Vaillant Boiler shows flow and/or return NTC fault?
    • M
      Melissa Parker MDSep 16, 2025
      If there is a flow and/or return NTC fault, the flow and/or return NTC is defective (tolerances too big). Replace the flow and/or return NTC.
  • K
    Katherine MorrisSep 23, 2025
    What to do if my Vaillant ecoTEC plus 615 Boiler has no communication to mainboard?
    • R
      Ronald RomanSep 23, 2025
      If there is no communication to the mainboard, there might be a connection error between the display and the mainboard. Check the connections to the mainboard.
  • A
    alanrichardsAug 27, 2025
    Why is there a large temperature spread in my Vaillant ecoTEC plus 615?
    • L
      lesliefoleyAug 27, 2025
      A large temperature spread between the flow and return probe in your Vaillant Boiler, indicating a water shortage, can be caused by a blocked or defective pump, or the pump output being too low. Inspect and repair or replace the pump.
  • V
    vargasmatthewAug 26, 2025
    What causes rapid temperature rise in my Vaillant Boiler?
    • P
      Perry SmithAug 27, 2025
      A rapid temperature rise in your Vaillant Boiler, indicating a water shortage, can be caused by a blocked pump, insufficient pump output, air in the appliance, low plant pressure, or interchanged flow and return NTCs. Inspect system for air and correct pump issues.
  • K
    Kevin LeblancAug 26, 2025
    Why does the flame go off during operation in my Vaillant ecoTEC plus 615 Boiler?
    • J
      Jason TurnerAug 26, 2025
      If the flame goes off during operation and subsequent ignition attempts fail in your Vaillant Boiler, it could be due to a temporarily stopped gas supply, spark failure in the ignition transformer, or faulty earthing of the appliance. Check gas supply and ignition system for faults.
  • M
    michelleclarkAug 25, 2025
    What to do if my Vaillant ecoTEC plus 615 is dry firing?
    • T
      Tina StoneAug 26, 2025
      If your Vaillant Boiler is dry firing, it indicates there may be too little water in the appliance, a defective water shortage switch, a defective cable to the pump or water shortage switch, a blocked or defective pump, or the pump output is too low. Ensure adequate water supply and check the water shortage switch and pump.

Summary

Introduction

Notes on the documentation

Explains manual structure, safety symbols, and applicable documents for clarity.

CE marking

Details CE marking compliance with EU directives for gas appliances and EMC.

Boiler specifications

Technical data

Comprehensive technical specifications including heat output, dimensions, gas/water pressures, and electrical data.

Dimensions

Visual representation of the boiler's physical dimensions and component layout.

General requirements

Installation site

Guidelines for selecting an appropriate installation location considering clearances and environmental factors.

Gas supply

Procedures for ensuring a safe and compliant gas supply connection to the boiler.

Electrical supply

Requirements for safe and compliant electrical connection, including fused supply and isolation.

Boiler installation sequence

Required minimum distances;assembly clearances

Specifies essential clearances around the boiler for installation, operation, and servicing.

Gas connection

Detailed instructions for performing a safe and leak-free gas connection to the appliance.

Electrical connection

Step-by-step guide for wiring the boiler, including main supply and control connections.

Commissioning Part I

Filling and bleeding the heating system

Procedures for filling and venting the heating system, ensuring correct pressure and water flow.

Checking the gas supply

Steps to verify gas inlet pressure and rate, crucial for safe and efficient boiler operation.

Functional checks (commissioning part II)

Functional checks

Essential checks to perform after installation to ensure the boiler operates correctly.

Handing over to the user

Guidance on instructing the user on safe operation, controls, and maintenance.

Inspection and maintenance

Initial inspection

Recommendations for preliminary checks before performing any servicing tasks.

Maintenance

Overview of regular maintenance tasks required for optimal boiler performance and longevity.

Servicing the burner module

Detailed instructions for the removal, servicing, and refitting of the burner module.

Troubleshooting

Logical fault finding procedure

A systematic guide to diagnose and resolve issues before referring to fault codes.

Status codes

Explanation of various status codes displayed by the boiler, indicating operational states.

Diagnostic codes

Details on accessing and interpreting diagnostic codes for advanced fault analysis.

Parts replacement

Safety instructions

Critical safety precautions to be followed before undertaking any component replacement.

Replacing burner

Step-by-step guide for the safe removal and replacement of the burner.

Replacing electronics and display

Procedures for replacing the boiler's electronic control board and display unit.

Recycling and disposal

Vaillant service

Vaillant ecoTEC plus 615 Specifications

General IconGeneral
ModelecoTEC plus 615
CategoryBoiler
Output15 kW
Dimensions (H x W x D)720 x 440 x 338 mm
Fuel TypeNatural Gas
MountingWall-mounted
Max. Working Pressure3 bar
NOx Emissions Class5
Flue OptionsHorizontal and Vertical
Heating Flow Temperature Range30°C to 80°C
Efficiency94% ErP