Instructions for installation and servicing
ecoTEC
Wall hung room sealed fan assisted condensing boiler
GB

Table of Contents

Questions and Answers

  • K
    Karen SimmonsSep 7, 2025
    What does it mean if my Vaillant Boiler shows eBUS undervoltage?
    • A
      ashley01Sep 7, 2025
      An eBUS undervoltage indication means there could be a short circuit on the eBUS, an overload on the eBUS, or two power sources on the eBUS with different polarity. Check the eBUS connections and power sources.
  • J
    jensenphillipAug 25, 2025
    What to do if the heating system of my Vaillant ecoTEC plus 624 Boiler is not full of water?
    • S
      Stacy GriffinAug 25, 2025
      If your Vaillant Boiler's heating system isn't full of water or charged correctly, make sure the heating system is full of water and charged to between 1 and 1.5 bar. If it's not, refill and vent the system.
  • W
    Wesley PattersonAug 25, 2025
    What to do if my Vaillant ecoTEC plus 624 Boiler is dry firing?
    • U
      umorrisAug 26, 2025
      If your Vaillant Boiler is dry firing, it indicates there may be too little water in the appliance, a defective water shortage switch, a defective cable to the pump or water shortage switch, a blocked or defective pump, or the pump output is too low. Ensure adequate water supply and check the water shortage switch and pump.
  • M
    Martha GriffithSep 16, 2025
    What to do if my Vaillant Boiler shows flow and/or return NTC fault?
    • C
      Cheryl WilliamsSep 16, 2025
      If there is a flow and/or return NTC fault, the flow and/or return NTC is defective (tolerances too big). Replace the flow and/or return NTC.
  • R
    Richard VincentSep 23, 2025
    What to do if the gas supply to my Vaillant Boiler is off?
    • K
      Kristin TurnerSep 23, 2025
      If the gas supply to your Vaillant Boiler is off or not correctly purged, check that the gas supply to the boiler is on, that it has been correctly purged, and that an inlet pressure of 20 mbar is available at the gas valve.
  • T
    Tracey OliverSep 12, 2025
    How to fix Return NTC short circuit in Vaillant ecoTEC plus 624 Boiler?
    • A
      Alexandra CastilloSep 12, 2025
      A Return NTC short circuit can be caused by a defective NTC, a short circuit in the cable harness, or a cable/casing shortcut. Replace the NTC and inspect the cable harness.
  • G
    greenesaraSep 2, 2025
    What causes a short circuit in the tank sensor of my Vaillant ecoTEC plus 624?
    • C
      Clayton FranklinSep 2, 2025
      A short circuit in the tank sensor of your Vaillant Boiler can be caused by a defective NTC, an earth leak/short circuit in the cable loom, or a damp plug connection. Inspect and replace the NTC or repair damp connections.
  • J
    john21Sep 3, 2025
    What does it mean 'No valid DSN in AI and/or BMU' in Vaillant Boiler?
    • M
      Mallory FisherSep 3, 2025
      If your Vaillant Boiler displays 'No valid DSN in AI and/or BMU', it indicates a spare part failure where the AI and motherboard were interchanged at the same time. Replace faulty components to resolve DSN issue.
  • M
    Margaret CopelandSep 23, 2025
    What to do if my Vaillant ecoTEC plus 624 has no communication to mainboard?
    • J
      James DavenportSep 23, 2025
      If there is no communication to the mainboard, there might be a connection error between the display and the mainboard. Check the connections to the mainboard.
  • B
    Bradley SmithAug 29, 2025
    What to do if there is a short circuit in the flow-NTC of my Vaillant ecoTEC plus 624?
    • M
      Maria JimenezAug 29, 2025
      If there is a short circuit in the flow-NTC of your Vaillant Boiler, it could be due to the NTC plug shorted to the casing or a defective NTC. Inspect and replace the NTC if defective.

Summary

Introduction and Documentation

Notes on Documentation

Details on manual usage, safety symbols, and applicable documents for clarity.

Introduction to ecoTEC Boilers

Overview of ecoTEC boiler types, features, and operation principles.

Safety Instructions and Symbols

Explains safety instructions and symbols for safe operation and installation.

Boiler Specifications

Technical Data

Detailed technical specifications including heat output, dimensions, gas pressure, and electrical data.

Dimensions and Clearances

Provides diagrams and measurements for boiler installation and required clearances.

General Installation Requirements

Related Documents and Standards

Lists relevant regulations, British Standards, and publications for boiler installation.

Installation Site Requirements

Specifies requirements for boiler location, space, ventilation, and frost protection.

Gas and Flue Pipe Requirements

Details gas supply connection and regulations for standard and optional flue systems.

Electrical Supply Requirements

Outlines mains electricity supply requirements, earthing, and connection methods.

Boiler Installation Sequence

Transporting and Positioning the Appliance

Guidance on safe manual handling and positioning of the boiler during installation.

Minimum Installation Distances

Specifies minimum clearances around the boiler for installation and servicing.

Gas and Heating Connections

Procedure for connecting the gas supply and heating system pipework.

Electrical Connection Details

Explains wiring procedures for connecting the boiler to the main electrical supply.

Controls and Accessories

Describes Vaillant controls, external electrical connections, and accessory compatibility.

Commissioning Procedures

Preliminary Checks

Covers initial checks for electrical supply, gas supply, and cold water systems.

Filling and Bleeding the Heating System

Guide on filling the heating system, bleeding air, and checking pressure.

Inspection and Maintenance

Overview of Inspection and Maintenance Tasks

Details annual inspection and maintenance tasks for safe boiler operation.

Servicing the Burner Module

Instructions for removing, cleaning, and refitting the burner module for maintenance.

Cleaning the Condensate Siphon

Procedure for cleaning the condensate siphon for proper drainage and safety.

Troubleshooting

Logical Fault Finding Procedure

A systematic approach to diagnosing and resolving common boiler faults.

Status and Diagnostic Codes

Explanation of status codes (S.x) and diagnostic codes (d.x) for appliance monitoring.

Parts Replacement

Safety Instructions for Parts Replacement

Crucial safety precautions before and during component replacement.

Replacing Key Components

Guidance on replacing common parts like the burner, fan, gas valve, and heat exchanger.

Appendix

EC Declaration of Conformity

Document certifying the boiler's compliance with relevant EC directives.

Benchmark Gas Boiler Commissioning Checklist

Checklist for ensuring proper installation, commissioning, and handover of the boiler.

Vaillant ecoTEC plus 624 Specifications

General IconGeneral
ModelecoTEC plus 624
CategoryBoiler
Output24 kW
Dimensions (H x W x D)720 x 440 x 338 mm
MountingWall-mounted
FuelNatural Gas
Warranty5 years
TypeCombination
Central Heating Flow Temperature Range30°C to 80°C