EasyManuals Logo

Vaillant ecoTEC plus 624 User Manual

Vaillant ecoTEC plus 624
184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
Supplied By www.heating spares.co Tel. 0161 620 6677
8 Instructions for installation and servicing ecoTEC
2.2 Dimensions
241
20
642
720
883
125
100100
440
35 35
130
180
300
ecoTEC plus 630:
334
ecoTEC plus 637,
ecoTEC plus 837:
368
175
190
65
75
45
8
6
4
3
2
1
5
7
10
9
12345
11
12
Fig. 2.1 Dimensions in mm
Legend:
1 Heating return pipe Ø 22 mm
2 Cold water connection Ø 15 mm (combination boilers only)
3 Gas connection Ø 15 mm
4 Hot water connection Ø 15 mm (combination boilers only)
5 Heating flow pipe Ø 22 mm
6 Hanging bracket
7 Flue hole - flue system 60/100
8 Flue hole - flue system 80/125
9 Spacer frame accessory (Art. No.: 308 650)
10 Flue pipe connection
11 Condensate drain connection (Ø 19 mm)
12 Heating system expansion relief valve connection (Ø 15 mm)
Note
With the spacer frame (Art. No 308 650), the
pipes can be run behind the boiler. The distance
of the appliance from the wall thus increases by
65 mm.
2 Boiler specifications

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vaillant ecoTEC plus 624 and is the answer not in the manual?

Vaillant ecoTEC plus 624 Specifications

General IconGeneral
ModelecoTEC plus 624
CategoryBoiler
Output24 kW
Dimensions (H x W x D)720 x 440 x 338 mm
MountingWall-mounted
FuelNatural Gas
Warranty5 years
TypeCombination
Central Heating Flow Temperature Range30°C to 80°C