12 Operating instructions 0020308119_02
Set the time periods on the heat generat-
or's control panel. ( Section 4.6.2)
Switching off heating mode
The heating mode can only be switched
off by decreasing the target room tem-
perature to the minimum value of 15 °C.
( Section 4.4.2)
Note
The level of the minimum target
room temperature can be de-
creased even further (5 °C), see
the operating and installation in-
structions for the room temperat-
ure control.
4.6.1 Switching the time control
on/off
Validity: Product with connected sensoROOM
pure (VRT 50/2)
1. Call up MAIN MENU CONTROL
Heating timer.
2. Activate On or Off.
4.6.2 Setting the time period using
the weekly planner
Validity: Product with connected sensoROOM
pure (VRT 50/2)
Set the time periods on the control panel
on the product instead of on the room
temperature control.
Call up MAIN MENU CONTROL
Heating timer Weekly planner.
Note
The weekly planner automatically
switches on the Heating timer
function if this function was deac-
tivated.
You can use a separate weekly planner
for heating mode for:
24 °C
18:0016:30
22:30
16 °C
21 °C
20:00
A
B
1
3
4
2
55 5
A Time
B Temperature
1 Time period 1
2 Time period 2
3 Desired temper-
ature
4 Set-back tem-
perature
5 Outside of the
time periods
Time periods are already set for each
day of the week at the factory.
You can divide a day up into several
time periods (3) and (5). Each time
period can comprise an individual start
time and end time. The time periods
must not overlap. You can assign a dif-
ferent desired temperature (1) to each
time period.
Example:
16:30 to 18:00; 21 °C
20:00 to 22:30; 24 °C
The living rooms are regulated to the de-
sired temperature within the time peri-
ods. In the times outside of the time peri-
ods (4), the living rooms are regulated to
the lower set-back temperature (2) that
is set.
For heating mode, you can save up
to 12 time periods for each day of the
week. You can set an individual desired
temperature for each time period. The
set desired temperature applies within
these time periods. The set-back tem-
perature applies outside of these time
periods.

Other manuals for Vaillant ecoTEC plus VU Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vaillant ecoTEC plus VU Series and is the answer not in the manual?

Vaillant ecoTEC plus VU Series Specifications

General IconGeneral
TypeCondensing Boiler
InstallationWall-mounted
Heating circuitSealed System
ErP RatingA
FuelNatural Gas
EfficiencyUp to 94%
Modulation1:6
Warranty2-5 years (depending on model and region)
Dimensions720 x 440 x 338 mm