Boiler specifications
Instructions for installation and servicing ecoTEC 839592_13 7
2
2 Boiler specifications
2.1 Technical data
Technical data
ecoTEC plus ecoTEC pro
Units
824 831 837 24 28
CH heat output range
80 °C flow/60 °C return
60 °C flow/40 °C return
50 °C flow/30 °C return
40 °C flow/30 °C return
6.7 – 19.0
6.9 – 19.6
7.1 – 20.2
7.2 – 20.6
8.7 – 24.0
9.0 – 24.7
9.2 – 25.5
9.4 – 26.0
12.0 – 28.0
12.3 – 28.9
12.7 – 29.7
12.9 – 30.3
6.7 – 19.0
6.9 – 19.6
7.1 – 20.2
7.2 – 20.6
9.0 – 24.0
9.3 – 24.7
9.6 – 25.5
9.8 – 26.0
kW
kW
kW
kW
Maximum DHW output 23.0 31.0 37 23.0 28.0 kW
Maximum output for heating 19 24 28 19 24 kW
Minimum output 6.7 8.7 12 6.7 9.0 kW
Category II
2H3P
SAP Seasonal Efficiency 88.5 88.9 88.8 88.89 88.8 %
Inlet gas working pressure required (G20, natural gas) 20
(mbar)
hPa
Inlet gas working pressure required (G31, Propane) 37
(mbar)
hPa
Connected load (if needed, related to stored charge/
water heating) at 15 °C and 1013 (mbar) hPa
G20: 2.5
G31: 1.82
G20: 3.3
G31: 2.46
G20: 4.0
G31: 2.94
G20: 2.5
G31: 1.82
G20: 3.0
G31: 2.22
m
3
/h
kg/h
Exhaust mass rate
at minimum thermal load (40 °C flow/30 °C return)
at maximum thermal load (80 °C flow/60 °C return)
3.2
10.7
4.2
14.4
5.7
17.1
3.2
10.7
4.4
13.0
g/s
g/s
Exhaust temperature
at minimum thermal load (40 °C flow/30 °C return)
at maximum thermal load (80 °C flow/60 °C return)
40
74
40
83
40
70
40
74
40
79
°C
°C
NOx class 5
Protection class IP X4D
max. flow temperature 85 °C
Adjustable flow temperature
Default setting: max. 75 °C
30 – 85 30 – 85 30 – 85 °C
Maximum CH system pressure (3.0) 0.3
(bar)
MPa
Circulation water volume (
T=20 K) 817 1032 1204 817 1032 l/h
Approx. condensation volume
at 50 °C flow/30 °C return heating
1.8 2.2 2.9 1.8 2.2 l/h
Pump delivery height 250
(mbar)
hPa
Minimum DHW flow rate 1.5 l/min
DHW flow rate
T=35 K rise 9.4 12.7 15.2 9.4 11.5 l/min
Appr. DHW flow rate at factory set temp. rise (
T=42 K) 7.9 10.6 12.6 7.9 9.6 l/min
Permitted DHW overpressure (10) 1
(bar)
MPa
Mains water pressure required for max. flow rate (0.5) 50 (0.75) 75 (0.75) 75 (0.5) 50 (0.5) 50
(bar)
kPa
Mains water pressure required for min. flow rate (0.15) 15
(bar)
kPa
Hot water discharge temperature range 35 – 65 °C
Exhaust flue 60/100 mm
Flue categories C13, C33, C43, C53, C83, B23, B33
10 l expansion vessel pre-charge pressure (0.75) 75
(bar)
kPa
Connections heating flow/return 22 mm
Gas inlet 15 22 15 mm
Pressure relief discharge pipework (min.) 15 mm
Condensate drain (min. internal drain) 19 mm
Dimensions (H x W x D)
720 x 440 x
335
720 x 440 x
369
720 x 440 x
403
720 x 440 x
335
720 x 440 x
369
mm
Weight (boiler only) 34 39 46 36 38 kg
Primary water content 1.9 2.3 2.5 1.9 2.1 l
Electrical supply voltage 230/50 V ~/Hz
Internal fuse (slow) main voltage 2 A
Power input 110 115 155 110 110 W
Table 2.1 T
echnical data ecoTEC combination boiler

Table of Contents

Other manuals for Vaillant ecoTEC pro

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vaillant ecoTEC pro and is the answer not in the manual?

Vaillant ecoTEC pro Specifications

General IconGeneral
ModelecoTEC pro
Fuel TypeNatural Gas
Efficiency RatingA
Dimensions (H x W x D)720 x 440 x 338 mm
ErP RatingA
MountingWall-mounted
TypeCombination Boiler
Efficiency89.3%
Output24 kW
Warranty2 years
Noise level49 dB

Related product manuals