EasyManuals Logo

Vaillant ecoTEC SERIES Instructions For Use

Vaillant ecoTEC SERIES
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
10 Instructions for use ecoTEC
4.5.2 Switching the warmstart function on and off
The warmstart system of the ecoTEC combination boi-
lers provides you with hot water at the required tempe-
rature immediately. To do this, the hot water heat
exchanger of the ecoTEC is kept at a pre-selected tem-
perature level and the boiler will therefore periodically
operate to maintain this temperature.
ecoTEC plus:
b
c
b
a
1
1
Fig. 4.10 Switching the warmstart system on and off with
ecoTEC plus
Activate the warmstart system by briefly turning the
knob (1) all the way clockwise (position a).
Then select the desired hot water outlet temperature
again, e.g. setting b (refer to Section 4.5.1). The appli-
ance automatically adapts the hot holding temperature
to the set hot water temperature. The tempered water is
directly available at the taps; the symbol
flashes in
the display.
Switch off the warmstart system by briefly turning the
knob (1) all the way anti-clockwise (position c). The
symbol
disappears. Then select the required hot
water outlet temperature again, e.g. setting b.
ecoTEC pro:
b
a
b
c
1
12
2
Fig. 4.11 Switching the warmstart system on and off with eco-
TEC pro
Activate the warmstart system by briefly turning the
knob (1) all the way clockwise (position a). The green
LED (2) lights up.
Then select the required temperature, e.g. setting b,
see 4.5.1.
The water is kept at a constant temperature of 55 °C
and is available immediately as you turn on a tap.
Switch off the warmstart system by briefly turning the
knob (1) all the way anti-clockwise (position c). The
green LED (2) goes out. Then select the required hot
water outlet temperature again, e.g. setting b.
4.5.3 Drawing hot water (ecoTEC combination boilers
only)
1
Fig. 4.12 Drawing off hot water (example: ecoTEC plus)
On opening a hot water tap (1) at a supply point (basin,
shower, bath, etc) the ecoTEC combination boiler will
automatically operate to deliver hot water.
On closing the tap the boiler switches OFF (or continues
to operate for central heating if required).
4 Operation

Other manuals for Vaillant ecoTEC SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vaillant ecoTEC SERIES and is the answer not in the manual?

Vaillant ecoTEC SERIES Specifications

General IconGeneral
ModelecoTEC SERIES
ErP RatingA
MountingWall-mounted
DimensionsVaries by model
WeightVaries by model
Fuel TypeNatural gas or LPG
NOx EmissionsClass 5 (less than 56 mg/kWh)
Output Range35kW

Related product manuals