30 Installation and maintenance instructions eloBLOCK 0020265768_01
Technical data Heating
VE 6 /14 EU I VE 9 /14 EU I VE 12 /14 EU I VE 14 /14 EU I
Heating adjustment range
25 to 85 25 to 85 25 to 85 25 to 85
Domestic hot water adjustment range
(with external cylinder)
35 to 70 35 to 70 35 to 70 35 to 70
Safety overheat cut-off device
95 95 95 95
Nominal volume flow (at ΔT = 10 K)
516 l/h 774 l/h 1,032 l/h 1,204 l/h
Pump remaining feed head (at ΔT =
10 K)
45 kPa
(450 mbar)
40 kPa
(400 mbar)
34.5 kPa
(345.0 mbar)
30 kPa
(300 mbar)
Number of immersion heaters (pcs x
kW)
2 x 3 1 x 3 and 1 x 6 2 x 6 2 x 7
VE 18 /14 EU I VE 21 /14 EU I VE 24 /14 EU I VE 28 /14 EU I
Heating adjustment range
25 to 85 25 to 85 25 to 85 25 to 85
Domestic hot water adjustment range
(with external cylinder)
35 to 70 35 to 70 35 to 70 35 to 70
Safety overheat cut-off device
95 95 95 95
Nominal volume flow (at ΔT = 10 K)
1,548 l/h 1,806 l/h 2,064 l/h 2,408 l/h
Pump remaining feed head (at ΔT =
10 K)
24 kPa
(240 mbar)
20 kPa
(200 mbar)
16.5 kPa
(165.0 mbar)
11 kPa
(110 mbar)
Number of immersion heaters (pcs x
kW)
3 x 6 3 x 7 4 x 6 4 x 7
Technical data Electrics
VE 6 /14 EU I VE 9 /14 EU I VE 12 /14 EU I VE 14 /14 EU I
Electrical connection
3 x 230 V/400 V + N
+ PE, 50 Hz
3 x 230 V/400 V + N
+ PE, 50 Hz
3 x 230 V/400 V + N
+ PE, 50 Hz
3 x 230 V/400 V + N
+ PE, 50 Hz
Protection class
IP40 IP40 IP40 IP40
Heating output
6 kW 9 kW 12 kW 14 kW
Power consumption, max.
3 x 9.5 A 3 x 14 A 3 x 18.5 A 3 x 23 A
Circuit stage
1.0 kW 1.0 kW 2.0 kW 2.3 kW
Nominal current rating for the fuse
10 A 16 A 20 A 25 A
VE 18 /14 EU I VE 21 /14 EU I VE 24 /14 EU I VE 28 /14 EU I
Electrical connection
3 x 230 V/400 V + N
+ PE, 50 Hz
3 x 230 V/400 V + N
+ PE, 50 Hz
3 x 230 V/400 V + N
+ PE, 50 Hz
3 x 230 V/400 V + N
+ PE, 50 Hz
Protection class
IP40 IP40 IP40 IP40
Heating output
18 kW 21 kW 24 kW 28 kW
Power consumption, max.
3 x 27.5 A 3 x 32 A 3 x 36.5 A 3 x 43 A
Circuit stage
2.0 kW 2.3 kW 2.0 kW 2.3 kW
Nominal current rating for the fuse
32 A 40 A 40 A 50 A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vaillant eloBLOCK VE 14 EU I Series and is the answer not in the manual?

Vaillant eloBLOCK VE 14 EU I Series Specifications

General IconGeneral
BrandVaillant
ModeleloBLOCK VE 14 EU I Series
CategoryBoiler
LanguageEnglish

Related product manuals