31GBInstallation instructions VRT 360f
9 Installation
9.1 Place of installation
The room temperature thermostat must
be installed to ensure that it can
properly record the room temperature
(away from heat traps, not mounted on
cold walls etc.).
The best place for installation is usually
in the main living room on an inside wall
at approx. 1.5 m height. There, the room
temperature thermostat should able to
record the circulating air, unhindered by
furniture, curtains or other objects.
Choose a location where the room
temperature thermostat is not affected
by draughts from doors or windows, or
by heat sources such as radiators,
chimney walls, televisions and direct
sunlight. All the radiator valves in the
room where the thermostat is installed
must be fully open.
9.2 Fitting the receiver
The connection of the receiver to the
boiler is via a 2-core bus cable (eBus).