9.1 Pump unit errors
No. 601
Pump control: Low level.
Description
The measured level is below the specified value.
Trouble shooting
This error can be caused by:
Low oil level
Mal functioning sensor
High value of Level Low limit
It can be solved by:
Refill the tank with oil
Decrease Level Low limit value
No. 602
Pump control: Temperature.
Description
The measured temperature is above or below the limit values.
Trouble shooting
This error can be caused by:
Low oil temperature
High oil temperature
Sensor malfunction
It can be solved by:
Change oil temperature
Adjust temperature Low limit
Adjust temperature High limit
No. 610
Pump control: Motor safety relay
Description
The motor protection relay is active
Trouble shooting
This error can be caused by:
Motor safety relay has been activated
Motor safety relay malfunction or disconnected