New Event Screen menu will be shown. Select Start Time. Select which Relay Type you want to follow the
Schedule and Select the Relay Duration of the contact closure. Select which Page Group(s) tone should go to.
Select Save.
NOTE: The contact closure pairs 13, 14, 15, 16 on the system punchdown block, should be wired to the tone
select input of an external tone generator (V-9927A). The tone output of the external tone generator should
then be wired to the external tone input of the V-2924A, pair 5 of the system punchdown block.