ULTIMATE
INSET LIVE FUEL EFFECT GAS FIRE
MODEL 417
OWNER GUIDE
THE NATURAL GAS MODEL IS FOR G20
AT A SUPPLY PRESSURE OF 20mbar
THE PROPANE GAS MODEL IS FOR G31
AT A SUPPLY PRESSURE OF 37mbar
THESE APPLIANCES ARE FOR USE IN THE UNITED KINGDOM (GB)
AND THE REPUBLIC OF IRELAND (IE) ONLY
THESE APPLIANCES ARE INSET LIVE FUEL EFFECT GAS FIRES.
THEY MUST NOT BE USED FOR ANY OTHER PURPOSE
This booklet is intended to help you use and care for your Valor gas fire
Please read thoroughly before using and keep for future reference.
We trust that these instructions give sufficient details to enable this appliance to be operated and
maintained satisfactorily. However, if you require further assistance, our Valor advice line will be
pleased to help - Ring 0345 626 341 (Local call rates apply).
If you need advice on any general matters concerning gas, the Gas Consumers’ Council (GCC) is an independent organisation which
protects the interests of gas users. You will find their telephone number in your local telephone directory under Gas.
600A936/03

Other manuals for Valor 417

Question and Answer IconNeed help?

Do you have a question about the Valor 417 and is the answer not in the manual?

Valor 417 Specifications

General IconGeneral
BrandValor
Model417
CategoryIndoor Fireplace
LanguageEnglish

Summary

CAUTION

Please note

Initial vapours from new appliances are harmless and disappear after a few hours.

GAS CONSUMPTION

OPERATING THE FIRE

Lighting with a taper

Procedure for lighting the pilot flame using a taper when the spark fails.

CLEANING

Metal parts

Clean metal parts with a damp cloth; avoid abrasive cleaners.

Coals and burner compartment walls

Handle RCF material carefully; brush soot off, avoid vacuum cleaners.

FUEL BED REFITTING

Rear wall

Place the ceramic rear wall into the back of the fire box.

Front base coal

Position the two halves of the front base coal in the burner compartment.

Rear base coal

Place the rear base coal behind the front coal, touching the rear ceramic wall.

Ceramic side walls

Place side walls marked 'L' and 'R' in the fire box and base coal recesses.

Front row outer coals

Place two remaining coals in outer valleys of front coal, ensuring pilot visibility.

Middle row of coals

Place three remaining coals behind and between front row coals.

MAINTENANCE

Debris from the chimney

Keep chimney clear; check annually for soot/mortar obstruction.

General servicing

Contact supplier for attention; annual checks recommended for safety.

Replacement Parts

List of ceramic fuel bed parts and their corresponding part numbers.

Related product manuals