Model 2100PKN 2100PKP 2200KN
2200LNK
2200RKN
2200KP
2200LKP
2200RKP
Gas Natural Propane Natural Propane
Altitude (Ft.)
0-4,500 feet
Input Maximum (Btu/h)
25,000 25,000 36,000 36,000
Input Minimum (Btu/h)
14,000 14,000 19,000 21,000
Manifold Pressure (in w.c.)
3.5” 10 4.0” 9.5”
Minimum Supply Pressure (in w.c.)
5” 11” 5” 11”
Maximum Supply Pressure (in w.c.)
10 14 10 14
Main Burner Injector Marking
DMS#42 DMS#53 DMS#32 DMS#49
Pilot Injector Marking
51 30 51 30
Min. Rate By-Pass Screw
185 125 220 160
General notes regarding conversion
We recommend that the gas conversion be done before the appliance is inserted in nal position into the cavity,
although it may be done after. The gas must be connected in order to set the manifold pressure.
WARNING
This conversion kit shall be installed by
a qualified service agency in accordance
with the manufacturer’s instructions and
all applicable codes and requirements
of the authority having jurisdiction. If
the information in these instructions is
not followed exactly, a fire, explosion
or production of carbon monoxide may
result causing property damage, personal
injury or loss of life. The qualified service
agency is responsible for the proper
installation of this kit. The installation
is not proper and complete until the
operation of the converted appliance is
checked as specified in the manufacturer’s
instructions supplied with the kit.
Use this manual in conjunction with the
installation manual supplied with the
appliance.
LX1 (2100NGK / 2100PGK)
LX2 (2200XNGK / 2200XPGK)
Gas Conversion Kits
INSTALLATION INSTRUCTIONS
LX Series
Use with Valor 2100PKN/PKP, 2200KN/KP, 2200LKN/LKP, and 2200RKN/RKP heaters ONLY
4007021-02
This appliance is certi ed for use from 04,500 feet. For
altitudes above 4,500 feet, see local codes.
Kit Contents
1 Pilot injector
1 Main burner injector
1 Set of conversion labels
1 bypass screw
Tools Required
Wrenches, to disconnect gas line
Small (jewelers size) at blade screwdriver, to set pres-
sure
• Small at blade screwdriver, to release pressure tap
on valve
Needle nose pliers, to remove by-pass screw
Hex (Allen) wrench, 4 mm or 5/32, to remove pilot injec-
tor
Manometer, to set manifold pressure at the valve
Appliance’s installation manual
Speci cations
© Copyright Miles Industries Ltd., 2019

Other manuals for Valor LX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Valor LX Series and is the answer not in the manual?

Valor LX Series Specifications

General IconGeneral
BrandValor
ModelLX Series
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals