4001533-04
VENTANA
WARNING
This conversion kit shall be installed by a
quali ed service agency in accordance with
the manufacturers instructions and all appli-
cable codes and requirements of the authority
having jurisdiction. If the information in these
instructions is not followed exactly, a re, ex-
plosion or production of carbon monoxide may
result causing property damage, personal in-
jury or loss of life. The quali ed service agency
is responsible for the proper installation of this
kit. The installation is not proper and complete
until the operation of the converted appliance
is checked as speci ed in the manufacturers
instructions supplied with the kit.
Use this manual in conjunction with the instal-
lation manual supplied with the appliance.
Gas Conversion Kit
1200PCK/NCK
Installation Instructions
This appliance is certi ed for use from 0–4500 feet. For
altitudes above 4500 feet, see local codes.
Kit Contents
1 Main burner
1 Pilot injector—see chart for identi cation
1 Main burner elbow injector—see chart for
identi cation
1 Minimum rate by-pass screw—see chart for
identi cation
1 Set of conversion labels
1 Ceramic middle log (NG 4001370; LPG 4001534)
Tools Required
Wrenches, to disconnect gas line
Phillips (+) screwdriver, to remove burner module
Small (jewelers size) at blade screwdriver, to set
pressure
Small at blade screwdriver, to release pressure tap
on valve
Nut driver 8 mm or 5/16”, to remove burner nuts
Needle nose pliers, to remove by-pass screw
Hex (Allen) wrench, 4 mm or 5/32”, to remove pilot
injector
Manometer, to set pressure when regulator is integral
with valve
Use with with Valor Models 1200 Heater ONLY
Model
1200NG 1200LPG
Gas Natural Propane
Altitude (Ft.)* 0-4,500 feet*
Input Maximum (Btu/h) 36,000 31,000
Input Minimum (Btu/h) 15,000 15,000
Manifold Pressure (in w.c.) 3.6 10.5
Minimum Supply Pressure (in w.c.) 5.0 11.0
Maximum Supply Pressure (in w.c.) 11.0 14.0
Main Burner Injector Marking 82-1200 92-360
Pilot Injector Marking 62 30
Min. Rate By-Pass Screw 190 125
Speci cations
© Copyright Miles Industries Ltd., 2014.
Question and Answer IconNeed help?

Do you have a question about the Valor VENTANA Series and is the answer not in the manual?

Valor VENTANA Series Specifications

General IconGeneral
CategoryFireplace Accessories
MaterialSteel
CompatibilityValor Fireplaces
FinishBlack
WeightVaries by model
DimensionsVaries by model

Summary

Installation Instructions Overview

Kit Contents

Lists the components included in the gas conversion kit for the Valor Ventana appliance.

Tools Required

Details the necessary tools for performing the gas conversion procedure on the appliance.

Conversion Procedure Start

General Notes Regarding Conversion

Provides general information and considerations for converting the Ventana fireplace between gas types.

Conversion Procedure Steps

Outlines the initial steps and factors influencing the conversion process, including burner module handling.

Component Replacement

Burner Module

Details the process for removing and replacing the main burner module for early and later model fixtures.

Injector Elbow

Instructions for reinstalling the main burner injector elbow, including air shutter considerations for NG units.

Pilot Injector

Guidance on removing and replacing the pilot injector with the correct one specified for the fuel type.

Valve and Pressure Adjustments

Minimum Rate By-Pass Screw

Describes how to access and replace the minimum rate by-pass screw on the appliance valve.

Manifold Pressure Setting

Details the two methods for setting manifold pressure based on regulator type, using a manometer.

Final Reassembly and Labeling

Burner Reinstallation & Check

Steps for reinstalling the burner module and checking gas connections for leaks after conversion.

Reinstall Ceramic Bricks and Logs

Instructions for correctly reinstalling the ceramic bricks and logs after the conversion.

Conversion Label Installation

Guidance on applying the conversion labels to the appliance data plate and access door.

Specifications Table

Related product manuals