EasyManua.ls Logo

Valor VOGUE Series User Manual

Default Icon
6 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Model
1300NG 1300LPG
Gas Natural Propane
Altitude (Ft.)* 0-4,500 feet*
Input Maximum (Btu/h) 30,000 28,000
Input Minimum (Btu/h) 6,500 14,500
Manifold Pressure (in w.c.) 3.7 10.5
Minimum Supply Pressure
(in w.c.)
5.0 11.0
Maximum Supply Pressure
(in w.c.)
10.0 14.0
Main Burner Injector Marking 850 300
Pilot Injector Marking 51 30
Min. Rate By-Pass Screw 125 125
Burner identi cation
VOGUE
4002604-01
©2012, Miles Industries Ltd.
Gas Conversion Kit
1300NGK/NPK
Installation Instructions
This appliance is certi ed for use from 0–4500 feet. For
altitudes above 4500 feet, see local codes.
Kit Contents
1 Pilot injector
1 Burner
1 Main burner elbow injector
1 Set of conversion labels
1 Set of air shutter
Tools Required
Wrenches, to disconnect gas line
Phillips (+) screwdriver, to remove burner module
Small (jewelers size)  at blade screwdriver, to set
pressure
Small  at blade screwdriver, to release pressure tap
on valve
Nut driver 8 mm or 5/16”, to remove burner nuts
Needle nose pliers, to remove by-pass screw
Hex (Allen) wrench, 4 mm or 5/32”, to remove pilot
injector
Manometer, to set pressure when regulator is integral
with valve
Speci cations
Use with with Valor Models 1300 Heaters ONLY
WARNING
This conversion kit shall be installed by a
quali ed service agency in accordance with
the manufacturers instructions and all appli-
cable codes and requirements of the authority
having jurisdiction. If the information in these
instructions is not followed exactly, a  re, ex-
plosion or production of carbon monoxide may
result causing property damage, personal in-
jury or loss of life. The quali ed service agency
is responsible for the proper installation of this
kit. The installation is not proper and complete
until the operation of the converted appliance
is checked as speci ed in the manufacturers
instructions supplied with the kit.
Use this manual in conjunction with the instal-
lation manual supplied with the appliance.
Question and Answer IconNeed help?

Do you have a question about the Valor VOGUE Series and is the answer not in the manual?

Valor VOGUE Series Specifications

General IconGeneral
VentingDirect Vent
MaterialSteel
Fuel TypeGas
BTU InputUp to 40, 000 BTU
EfficiencyUp to 80%
Ignition SystemElectronic Ignition
FinishVarious finishes available
CompatibilityCompatible with Valor

Summary

Critical Safety Warning

General Notes Regarding Conversion

Provides general information about performing the conversion and gas connection requirements.

Installation Steps

Prepare the Appliance

Instructions for removing fireplace components to access the burner.

Replace the Burner

Procedure for disconnecting and replacing the main burner.

Convert the Pilot Injector

Guide for removing the old pilot injector and installing the new one.

Set Manifold Pressure and Aeration

Steps to adjust gas pressure using a manometer and check airflow.

Reinstall Fireplace Components

Instructions for reassembling the fireplace after conversion.

Fit Conversion Labels

Guidance on applying new specification and conversion labels.

Technical Specifications