PP500 Installation Guide 11
ENG
Preset Congurations (short commands)
In programming mode, you can select different
congurations by using short codes. After select-
ing the pre-dened conguration the reader will
return to programming mode.
These are key presses and after pressing A there
is only one key press between values 0 to 9.
Com-
mand
Function
A1 Precongured interface BCLINK (for
Vanderbilt Entro)
A2 Precongured interface 12 (26 bit
Wiegand)
A3 Precongured interface BE (Clock &
Data)
A4 Precongured interface 59 (48 bit
Wiegand for Granta)
The Precongured interfaces is stored in non-vola
-
tile memory. Any other parameters such as LED
control and horn control will be dened later and
will only apply for A2, A3 and A4.
A3 Precongured is interface BE (Clock & Data),
with external control of Red LED, Green LED and
Horn. Also, the yellow LED is not active at all,
showing no indication of noise or key presses.