PP500 Installation Guide 15
ENG
A
Power in, terminal nos 1(+) and 2. 12-24 Vdc.
B
Terminal blocks 3 & 4 are used for BCLINK Com
C and Com D (pre-congured interface A1).
The connections 3 & 4 changes function when
preset conguration A2, A3 or A4 are selected.
See table of connections for each host system.
Default: Com C and Com D.
C
Terminal blocks 5, 7, 8, 9 & 10 can be used in
preset conguration A2, A3 or A4. See table of
connections for each host system.
D
Entry or Exit selection (sub-addressing technique
in BCLINK). Default: ENTRY.
E
INT = Internal tamper function (in BCLINK sent
digitally signal to system). No hardware signal on
connection 11 & 12.
EXT = The tamper status signal exists on 11 & 12.
Both jumpers must be placed on the same selec-
tion. Default: INT.
F
Selection of logic for tamper switch.
NC= Closed when the housing is closed.
Default: NC.
G
Tamper switch connection, terminal nos 11 and
12. Default: Not used.
H
Optional resistor 10 kohm for tamper monitoring.
Used in serial with tamper switch.
Default: Not used.
I
Mechanical tamper switch.
J
Buzzer.