CONDITIONING PLANTS
SPLIT and COMPACT models
page 21
www.climma.it
4 ELECTRICAL CIRCUIT
4.9 - FAN SPEED - C305
The fan can run on three speeds. It is possible to modify the max speed installing an optional capacitor as
indicated in schematic, removing the existing bridge.
IMPORTANT NOTE: The run capacitor (CM) is specific for
each fan motor and must not be modified as a different value will let
the fan motor burn.
AC POWER
GN L N
CM
C1
C2
C3
EB
OPTION
M60465
1 2 N 3
FAN
B N
N
B
E
E
D
D
1M.
PUMP
NL
GN
DELAY
11A2
MODELLO C.M.
C3
Compact 5 - split 4 EV*
Compact 9 - split 8 EV
Compact 12 - split 10 EV
Compact 17 - split 16 EV
COD. C2 C1
2
4
2
6.3
M3502
M3502
M3503
M3505
-
-
8
8
2
3.15
2
4
4
4
5
8
TABELLA VALORI CONDENSATORI DEL VENTILATORE
Compact 17 slim - split 17 slim
Compact 24 slim - split22 slim
4 M3502 10
2
8
8 M3504 -
6.3
10
FAN CAPACITOR TABLE