12
ENGLISH
8 - TROUBLE SHOOTING
The air filter is dirty
Clean or replace the air filter.
6,5 - THE HEATING IS NOT SUFFICIENT - EH VERSION.
Have you selected the correct mode?
Select on the panel the AUTO (A) mode
Have you correctly set the thermostat?
Set the temperature on higher values.
The fan speed is too high
Decrease the fan speed or select the AUTO mode
The air circulation is poor
Check that there are no obstructions on the outlet and inlet grills and that the air filter is cleaned.
The air filter is dirty
Clean or replace it.
The heating is working only for few minutes
The resistance protection device is tripping. Check the air circulation, the fan speed and the air filter.
If this happens again, call the nearest Service Dealer.
6.6 - THE SEA WATER PUMP DOESN'T WORK
Is the fuse burned?
After the necessary checks, replace the F1 fuse with another one with the same dimension and
value.
Is the high pressure switch device snapped?
Check the cooling circuit and clean the strainer on the sea water intake. If this happens again, call
the nearest Service Dealer.