Vacuum Instrument Corp.
2099 Ninth Avenue
Ronkonkoma, NY 11779
631.737.0900
‘Y’ - Followed by 3 to 4 characters.
Fine Crossover Delay (D1) in Tenths of seconds.
(e.g. 0.1 = 0.1 seconds)
(e.g. 14.2 = 14.2 seconds)
In software revisions 3.8 and later, this field is fixed at 5
characters.
(‘Y’ + 4 numbers).
(e.g. 0010 = 1.0 seconds)
‘Z’ - Followed by 3 to 4 characters.
Direct Rough Close Delay (D2) in Tenths of seconds.
(e.g. 7.2 = 7.2 seconds)
(e.g. 21.7 = 21.7 seconds)
In software revisions 3.8 and later, this field is fixed at 5
characters.
(‘Z’ + 4 numbers).
(e.g. 0010 = 1.0 seconds)
‘[‘ - Followed by 3 to 4 characters.
Vent Valve Open Delay (D3) in Tenths of seconds.
(e.g. 1.0 = 1.0 seconds)
(e.g. 15.2 = 15.2 seconds)
In software revisions 3.8 and later, this field is fixed at 5
characters.
(‘[‘ + 4 numbers).
(e.g. 0010 = 1.0 seconds)
‘\ ’ - Followed by 3 to 4 characters.
Vent Valve Close Delay (D4) in Tenths of seconds.
(e.g. 2.0 = 2.0 seconds)
(e.g. 10.3 = 10.3 seconds)
In software revisions 3.8 and later, this field is fixed at 5
characters.
(‘\ ’ + 4 numbers).
(e.g. 0010 = 1.0 seconds)