Aluminum chloride
anhydrou
s
(AlCl
3
)
1-5% 7446-70-0
R14, R22, R37, R41, R43.
S2, S8, S22, S24, S26,
S36, S45
Carbon
(C
n
)
3-4% 1333-86-4 NONE KNOWN
Amount varies depending on cell size.
4. First Aid Measures
Inhalation
Remove from exposure, rest and keep warm.
In severe cases obtain medical attention.
Skin contact
Wash off skin thoroughly with water. Remove contaminated clothing and
wa
sh before reuse. In severe cases obtain medical attention.
Eye contact
Irrigate thoroughly with water for at least 15 minutes.
Obtain medical attention.
Ingestion
Wash out mouth thoroughly with water and give plenty of water to drink.
Obtain medi
cal attention.
Further treatment
All cases of eye contamination, persistent skin irritation and casualties who
have swallo
wed this substance or been affected by breathing its vapours
should be seen by a doctor.
5. Fire Fighting Measures
CO extinguishers or, even preferably, copious quantities of water or water-based foam, can be used to cool
down burning Li-SOCl cells and batteries, as long as the extent of the fire ha s not progressed to the point
that the lithium metal they contain is exposed (marked by deep red flames).
2
2
Do not use for this purpose sand, dry powder or soda ash , graphite powder or fire blankets.
Use only metal (Class D) extinguishers on raw lithium.
Extinguishing media
Use water or CO
2
on burning Li-SOCl
2
cells or batteries
and class D fire extinguishing agent only on raw lithium.
6. Accidental Release Measures
Remove personnel from area until fumes dissipate. Do not breathe vapours or touch liquid with bare hands.
If the skin has come into contact with the electrolyte, it should b
e washed thoroughly with water.
Sand or earth should be used to absorb any exuded material. Seal
leaking battery and contaminated
absorbent material in plastic bag and dispose of as Special Waste in accordance with local regulations.
MSDS Li-SOCl
2
Rev. 8 October 2008

Other manuals for Veeder-Root TLS-350 PLUS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Veeder-Root TLS-350 PLUS and is the answer not in the manual?

Veeder-Root TLS-350 PLUS Specifications

General IconGeneral
CategoryMeasuring Instruments
Number of Tanks SupportedUp to 16
Water DetectionYes
Inventory ManagementYes
Delivery ReportingYes
Alarm ManagementYes
DisplayLCD
EnclosureNEMA 4X
ModelTLS-350 PLUS
ManufacturerVeeder-Root
Temperature MeasurementYes
TypeAutomatic Tank Gauge
Leak DetectionYes
CommunicationRS-232, Ethernet
Product TypeTank Gauging System
ComplianceUL, ATEX