Level and Pressure
Operating Instruction
Capacitive electrodes EL
4 … 20 mA - compact

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Vega EL 53 and is the answer not in the manual?

Vega EL 53 Specifications

General IconGeneral
BrandVega
ModelEL 53
CategoryMeasuring Instruments
LanguageEnglish

Summary

Product Description

Function and Configuration

Explains how capacitive electrodes detect levels using capacitance and resistance principles.

Types and Versions

Details various EL electrode types, their versions, and available features like insulation and approvals.

Technical Data

Provides comprehensive specifications for housing, connections, electrode materials, and operating conditions.

Approvals

Covers explosion protection, overfill protection, ship approvals, and CE conformity for safe operation.

Dimensions

Presents detailed drawings and measurements for different EL electrode models and their components.

Type Plate

Explains the essential data and configuration details found on the instrument's identification plate.

Mounting

Mounting Instructions

Guides on proper installation, considering lateral load, extraction forces, and vessel pressure for reliable measurement.

Electrical Connection

Connection Instructions

Details safe procedures for connecting the sensor, including supply voltage and cable screening.

Wiring Plan

Illustrates sensor wiring to terminals and connection to indicating instruments or DCS systems.

Set-up

General Adjustment

Outlines methods for adjusting the electrode using integrated oscillator, VVO software, or HART®-handheld.

Adjustment - Oscillators CAP E32 Ex and CAP E32 Η Ex

Step-by-step guide for adjusting MIN, MAX, integration time, and other parameters on the oscillator.

Adjustment with VVO

Describes using VEGA Visual Operating (VVO) software for detailed sensor configuration and adjustment via PC.

Adjustment with HART®-handheld

Explains how to use a HART®-handheld device for sensor adjustment, including multidrop and burst operations.

Diagnosis

Simulation

Allows simulating filling levels to test connected instruments and alarm functions.

Maintenance

States that the instrument is maintenance-free.

Repair

Provides instructions for returning defective instruments to VEGA-staff for repair.

Failure Removal

Offers troubleshooting guidance for common sensor failures, including checks and potential causes.