EasyManuals Logo

Vega VEGACAL 63 Specification Sheet

Vega VEGACAL 63
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
VEGACAL 63 - 34606-EN-160112VEGA Grieshaber KG, Am Hohenstein 113, 77761 Schiltach/Germany, www.vega.com
Specication sheet
VEGACAL 63
4 … 20 mA/HART - two-wire
Capacitive rod electrode for continuous level measurement
Application area
The VEGACAL 63 level sensor can be used universally for the meas-
urement of conductive and non-conductive liquids. The rod electrode
is fully insulated and the proven mechanical construction ensures high
functional safety.
Your benet
Long lifetime and low maintenance requirement through robust me-
chanical construction
Savings through simple mounting and setup
Maximum utilisation of vessel, because measurement over entire
probe length
Function
Sensor and vessel form the two electrodes of a capacitor. A capaci-
tance change caused by a level change is evaluated by the integrated
electronics and converted into an appropriate output signal. The level
measurement is carried out over the entire sensor length without a
blocking distance.
Technical data
Measuring range 6 m (19.69 ft)
Process tting Thread from G½, ½ NPT, anges from
DN 50, 2"
Process pressure -1 … +64 bar/-100 … +6400 kPa
(-14.5 … +928 psig)
Process temperature -50 … +200 °C (-58 … +392 °F)
Ambient, storage and
transport temperature
-40 … +80 °C (-40 … +176 °F)
Operating voltage 12 … 36 V DC
SIL qualication Optionally up to SIL2
Materials
The wetted parts of the instrument are fully PTFE or PE insulated.
You will nd a complete overview of the available materials and seals in
the "congurator" on our homepage at www.vega.com/congurator.
Housing versions
The housings are available as single chamber or double chamber ver-
sion in plastic, stainless steel or aluminium.
They are available with protection ratings up to IP 68 (1 bar).
Electronics versions
The instruments are available in dierent electronics versions. Apart
from the two-wire electronics with 4 … 20 mA/HART, there are two pure
digital versions with Probus PA and Foundation Fieldbus possible as
well as one version for connection to a signal conditioning instrument.
Approvals
The instruments are suitable for use in hazardous areas and are ap-
proved e.g. according to ATEX and IEC. The instruments also have
various ship approvals such as e.g. GL, LRS or ABS.
You can nd detailed information at www.vega.com/downloads and
"Approvals".

Other manuals for Vega VEGACAL 63

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vega VEGACAL 63 and is the answer not in the manual?

Vega VEGACAL 63 Specifications

General IconGeneral
BrandVega
ModelVEGACAL 63
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals