Number of bytes Sign
T3 1 %
End identication 1 CR
l T1: "=" (1 sign)
l DCS no.: No. of the PC/DCS output as 3-digit decimal
number
l T2: "#" (1 character)
l Value: Numerical value of the PC/DCS output or in case of
faulty measured value the text "FAULT"
Formatting of the value:
Sign Meaning
1
"- ": Minus with negative numbers
" ": Space with positive numbers
2 4 3-digit number
5 ".": Decimal point
6 1-digit number (after the decimal point)
l T3: "%" (1 character)
l End identication: Carriage Return CR (1 sign)
Total length of the telegram: N*12 13 signs
Note:
The % sign is a separator, not the unit %
Enquiry:
%
Answer:
=001# 067.3%
=002# 824.6%
=003#-067.3%
=004# 824.6%
2.6.1 % Block enquiry with length
As answer to the range enquiry, the range stated in the enquiry
with PC/DCS values is delivered. The measured value is
transmitted with three decimal places in front of the decimal
point and one decimal place after the decimal point without
unit.
Example:
Modbus-TCP, VEGA ASCII protocol - VEGAMET 624/625, VEGASCAN 693, PLICSRADIO 15
VEGA ASCII protocol
30768-EN-070730