Answer:
=001# 824.6 #kg
2.9.1 $ Block enquiry
As answer to the block enquiry, all assigned PC/DCS values in
the instrument are delivered. The measured value is trans-
mitted with 11 decimal places as oating point and with unit.
Number of bytes Sign
Identier 1 $
End identication 1 CR
l Identier: "$" (1 character)
l End identication: Carriage Return CR (1 sign)
Total length of the telegram: 2 characters
"N"-times repetition of the following telegram
(N=total number of assigned PC/DCS outputs)
Number of bytes Sign
T1 1 =
DCS no. 3 001 030
T2 1 #
Value 11 -824.6
T3 1 #
Unit 0 n xxx
End identication 1 CR
l T1: "=" (1 sign)
l DCS no.: No. of the PC/DCS output as 3-digit decimal
number
l T2: "#" (1 character)
l Value: Numerical value of the PC/DCS output or with
interferred measured value the error code "Exxx"
Formatting of the value:
Sign Meaning
1
"- ": Minus with negative numbers
" ": Space with positive numbers
2 12 11-digit number with comma or error code
Enquiry of the control system
Answer from the signal con-
ditioning instrument
Modbus-TCP, VEGA ASCII protocol - VEGAMET 624/625, VEGASCAN 693, PLICSRADIO 31
VEGA ASCII protocol
30768-EN-070730